ean | 4015081004980 | ||
product height | 80 mm | ||
Product weight | .75 kg | ||
certifications | csa (class no. 1432-01) csa certified ul (file no. e140305) ul (category control number dihs) ce marking csa-c22.2 no. 5-09 ul489 csa (file no. 22086) ul listed iec60947 |
||
frame | nzm3 | ||
suitable for | copper cable lugs three-pole |
||
amperage rating | 630 a | ||
terminal capacity (copper strip) | 10 segments of 50 mm x 1 mm (2x) | ||
terminal capacity (flexible cable) | 300 mm² (2x) 500 awg/kcmil (2x) |
||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
special features | one hole | ||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
number of poles | three-pole | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. |
product length/depth | 6 mm | ||
product width | 188 mm | ||
compliances | iec ul/csa rohs conform |
||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
terminal capacity (copper busbar) | 10 mm x 50 mm (2x) | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
Type | accessory connection width extension terminal |
||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 inscriptions | meets the product standard's requirements. | ||
used with | nzm3, pn3, n(s)3 | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. |