Valve function | 2x2/2-way, monostable, closed 2x2/2-way, open/closed, monostable 2x3/2-way, monostable, closed 2x3/2-way, open, monostable 2x3/2-way, open/closed, monostable 5/2 double solenoid 5/2-way, monostable Vacuum generator Vacuum generator + 2/2-way, closed, monostable | ||
Max. standard nominal flow rate | 400 l/min at 10 mm | ||
Operating pressure | -0,9 bar ... 10 bar | ||
Max. number of valve positions | 8 | ||
Electrical I/O system | yes | ||
Degree of protection | IP65 | ||
KC mark | KC-EMV | ||
Explosion protection certification outside the EU | NEC 500 Class I, Div. 2 | ||
Explosion ignition protection type for gas | Ex nA IIC T4 X Gc | ||
Nominal size | 4 mm | ||
Sealing principle | Soft | ||
Design | Piston gate valve | ||
Pilot air supply | External Internal | ||
Signal status display | LED | ||
Pilot pressure | 3 bar ... 8 bar | ||
Nominal operating voltage DC | 24 V | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 1 - Low corrosion stress 2 - Moderate corrosion stress | ||
Media temperature | -5 °C ... 50 °C | ||
Pilot exhaust port 82/84 | Common line | ||
Pneumatic connection, port 2 | M7 | ||
Pneumatic connection, port 4 | M7 |
Valve size | 10 mm | ||
pneumatic working port | M7 QS-4 QS-6 QS-1/8 QS-1/4 | ||
Electrical control | AS-Interface CPI installation system Individual connection Fieldbus Multi-pin plug | ||
Max. number of pressure zones | 2 | ||
Ambient temperature | -5 °C ... 50 °C | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Explosion Protection Directive (ATEX) | ||
ATEX category gas | II 3G | ||
Explosion ambient temperature | -5°C <= Ta <= +50°C | ||
Type of actuation | Electric | ||
Terminal type | 10 | ||
Max. number of valve functions | 16 | ||
Valve terminal structure | Fixed grid | ||
Note on operating pressure | 0 - 0.8 MPa with ext. pilot air 0 - 8 bar with external pilot air | ||
Suitability for vacuum | yes | ||
Explosion protection | Zone 2 (ATEX) Class I, Div. 2 (US) | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Storage temperature | -20 °C ... 40 °C | ||
Pilot air port 12/14 | Common line | ||
Pneumatic connection, port 1 | Common line | ||
Pneumatic connection, port 3 | Common line | ||
Note on materials | RoHS-compliant |