Material piston rod | High-alloy stainless steel | ||
Material housing | Die-cast aluminium | ||
Type of mounting | In-line installation With accessories Either: | ||
Certificate issuing authority | IFA 1001180 TÜV 44 799 12 556236 000 | ||
KC mark | KC-EMV | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Storage temperature | -10 °C ... 60 °C | ||
Media temperature | -10 °C ... 60 °C | ||
Note on materials | RoHS-compliant | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Characteristic coil data | 110 V AC: 50/60 Hz, pick-up power 3.0 VA, holding power 2.4 VA 230 V AC: 50/60 Hz, pick-up power 3.0 VA, holding power 2.4 VA 24 V DC: 1.5 W 24 V DC: 1.8 W | ||
Duty cycle | 100% | ||
Pressure gauge (ANALOG) or Pressure display (DIGITAL) | Prepared for G1/4 Prepared for G1/8 Red/green scale Via pressure sensor With pressure sensor with LCD display With pressure sensor with operational status indicator With pressure gauge | ||
Valve function | 3/2-way, closed, monostable Soft-start function | ||
Type of reset | Mechanical spring | ||
Exhaust-air function | Without flow control option | ||
Pilot air supply | Internal | ||
Design | Piston gate valve Piston seat | ||
Safety function | Exhaust Prevention of unexpected start-up (pressurisation) | ||
Size | 6 |
Material seals | NBR | ||
Mounting position | optional | ||
Suitable for use with food | See supplementary material information | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EC Machinery Directive To EU Low Voltage Directive | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Ambient temperature | -10 °C ... 60 °C | ||
Degree of protection | IP65 With plug socket | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Signal status display | LED Floating contact Switching outputs Via AS-i | ||
Standard nominal flow rate | 4.300 l/min ... 5.700 l/min | ||
Operating pressure | 3 bar ... 10 bar | ||
Type of piloting | Pilot actuated | ||
Manual override | None On pilot solenoid valves: non-detenting; on soft-start/quick exhaust valve: detenting, self-resetting On pilot solenoid valves: non-detenting, detenting; on soft-start/quick exhaust valve: detenting, self-resetting | ||
Sealing principle | Soft | ||
Type of actuation | Electric | ||
Note on forced dynamization | Switching frequency min. 1/month | ||
Grid dimension | 62 mm | ||
Series | MS |