Number of diagnostic outputs | 2 | ||
Mounting position | Free convection Vertical | ||
Display | Green/yellow/red LED | ||
Conforms to standard | EN 61800-3 EN 61800-5-1 EN 61800-5-2 EN ISO 13849-1 | ||
Approval | RCM trademark German Technical Control Board (TÜV) c UL us listed (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EC Machinery Directive In accordance with EU RoHS Directive | ||
Certificate issuing authority | German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 TÜV Rheinland UK Ltd. 01/205U/5640.00/22 UL E331130 | ||
Ambient temperature | 0 °C ... 50 °C | ||
UL ambient temperature | 0 °C ... 40 °C | ||
Max. installation height | 2.000 m | ||
Degree of protection | IP20 | ||
Overvoltage category | III | ||
Immunity to surge | 6 kV | ||
LABS (PWIS) conformity | VDMA24364 zone III | ||
Nominal operating voltage AC | 400 V | ||
Input voltage range AC | 200 V ... 480 V | ||
Nominal current, load supply | 15 A | ||
Active PFC | no | ||
System voltage to EN 61800-5-1 | 300 V | ||
Mains types | TN IT | ||
Permissible range for load power supply | ± 10 % | ||
Brake resistor, integrated | 47 Ohm | ||
Pulse energy for braking resistor | 1.200 Ws | ||
Brake resistor, external | 40 Ohm ... 60 Ohm | ||
Nominal voltage for logic power supply DC | 24 V | ||
Current consumption of logic power supply without clamping brake | 0,5 A | ||
Max. current consumption, logic power supply with clamping brake and I/O | 2,5 A | ||
Nominal current per phase, effective | 12 A | ||
Max. peak current duration | 2 s | ||
Maximum output | 18.000 VA | ||
Max. length of motor cable without external mains filter | 25 m | ||
Max. voltage drop from logic supply to brake output | 1 V | ||
Controller operating mode | Cascade controller P position controller PI speed controller PI current regulator for F or M Profile operation with record and direct mode Interpolated mode via fieldbus Synchronised operating modes Homing Setting-up Autotuning | ||
Ethernet interface, function | Parameterisation and commissioning | ||
Field bus, protocol | EtherNet/IP Modbus/TCP | ||
Fieldbus link | EtherNet/IP Modbus/TCP | ||
Process interfacing | Adjustable-speed drives Drives with positioning function | ||
Field bus, connection type | 2x socket | ||
Encoder interface, function | ENDAT® 2.1 encoder EnDat® 2.2 encoder Hiperface-Geber Incremental encoder Nikon SIN/COS encoder | ||
Synchronisation interface, function | Encoder emulation A/B/Z Encoder input A/B/Z | ||
Encoder interface input, features | 1 MHz maximum output frequency Max. 16384 ppr | ||
Switching logic for inputs | PNP (positive switching) | ||
Specification logic input | Based on IEC 61131-2, type 3 | ||
Number of high-speed logic inputs | 2 | ||
Number of digital logic outputs 24 V DC | 6 | ||
Features of digital logic outputs | Freely configurable in some cases Not galvanically isolated Diagnostics outputs in some cases | ||
Number of high-speed switching outputs | 2 | ||
Number of floating switching outputs | 1 | ||
Number of analogue setpoint inputs | 1 | ||
Working range setpoint input | ± 10 V | ||
Impedance of setpoint input | 70 kOhm | ||
Safety Integrity Level (SIL) | Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3 | ||
Diagnostic coverage | 97 % | ||
Hardware fault tolerance | 1 |
Type of mounting | Mounting plate, attached with screws | ||
Product weight | 4.100 g | ||
Operator controls | Optional: CDSB operator unit | ||
Based on standard | EN 50581 EN 60204-1 EN 61508-1 EN 61508-2 EN 61508-3 EN 61508-4 EN 61508-5 EN 61508-6 EN 61508-7 EN 61800-2 EN 62061 | ||
KC mark | KC-EMV | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK regulations for machines To UK RoHS instructions | ||
Storage temperature | -25 °C ... 55 °C | ||
Note on ambient temperature | Power must be reduced by 3% per °C at ambient temperatures above 40°C. | ||
Relative air humidity | 5 - 90% Non-condensing | ||
Note on max. installation height | From 1000 m: power reduction by 1% per 100 m. | ||
Protection class | I | ||
Pollution degree | 2 | ||
Note on materials | RoHS-compliant | ||
Phases of nominal operating voltage | 3-phase | ||
Permissible voltage fluctuations | +/- 10 % | ||
Mains frequency | 48 Hz ... 62 Hz | ||
Peak current load power supply | 45 A | ||
Mains filter | Integrated | ||
Max. short circuit current rating of the mains | 10 kA | ||
Nominal voltage load voltage DC | 560 V | ||
Max. intermediate circuit voltage DC | 800 V | ||
Pulse power, brake resistance | 13,6 kVA | ||
Nominal power braking resistor (IEC) | 100 W | ||
Max. continuous output of the external braking resistor (IEC) | 3.000 W | ||
Permissible range for logic voltage | ± 20 % | ||
Current consumption for logic supply with parking brake | 2 A | ||
Output voltage class AC | 3x (0 – input) V | ||
Peak current per phase, effective | 36 A | ||
Controller nominal output | 6.000 VA | ||
Output frequency | 0 Hz ... 599 Hz | ||
Max. output current of holding brake | 1,5 A | ||
Number of inputs for motor temperature sensor | 1 | ||
Operating mode of drive unit | Field-oriented closed-loop control Position resolution 24 bit/rev Sampling rate 16 kHz PWM at 8 or 16 KHz Vector modulation with 3rd harmonic Real-time data acquisition 2x input capture (x, v, F) 2x output trigger (x, v, F) 2x position encoder input 1x SYNC interface for encoder emulation or encoder input | ||
Ethernet interface, protocol | TCP/IP | ||
Fieldbus interface, function | Bus connection incoming/outgoing EtherNet/IP slave | ||
Communication profile | DriveProfile | ||
Field bus interface, transmission rate | 100 Mbit/s | ||
Field bus, connection system | RJ45 | ||
Encoder interface 2, function | Incremental encoder SIN/COS encoder | ||
Encoder interface output, features | 1 MHz maximum output frequency Max. 16384 ppr | ||
Number of digital logic inputs | 12 | ||
Features of logic input | Freely configurable in some cases Safety inputs in some cases Not galvanically isolated | ||
Working range of logic input | -3 V ... 30 V | ||
Time resolution of high-speed logic inputs | 1 µs | ||
Switching logic for outputs | PNP (positive switching) | ||
Max. current digital logic outputs | 20 mA | ||
Time resolution of high-speed switching outputs | 1 µs | ||
Max. current of the floating switching outputs | 50 mA | ||
Features of setpoint inputs | Differential inputs Configurable for speed Configurable for current/force | ||
Working range of analogue inputs | ± 10 V | ||
Safety function | Safe brake control (SBC) Safe torque off (STO) Safe Stop 1 (SS1) | ||
Performance Level (PL) | Safe brake control (SBC)/category 3, performance level e Safe Torque Off (STO)/category 4, performance level e | ||
SFF Safe Failure Fraction | 99 % | ||
Number of safe 2-pin inputs | 2 |