Dimensions (W x L x H) | (incl. interlinking block and connection technology) 50 x 107 x 50 mm | ||
Diagnosis | Wire break per channel Limit value violation per channel Short circuit of output signal per channel Short circuit of actuator supply Parameterisation error Undervoltage of outputs | ||
LED display | 1 Group diagnostics | ||
Repetition accuracy | 0.05% at 25ºC | ||
Operational voltage range DC | 18 V ... 30 V | ||
Operating error limit related to the ambient temperature range | ±0.6% | ||
Nominal operating voltage DC | 24 V | ||
Isolation channel - channel | no | ||
Storage temperature | -20 °C ... 70 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Data format | 12 bits + prefix Scalable to 15 bits | ||
Sensor type | 0 - 10 V 0 - 20 mA 4 - 20 mA |
Number of outputs | 2 | ||
Parameterisation | Data format Fail-safe per channel Forcing per channel Limit monitoring per channel Idle mode per channel Measured value smoothing Signal range per channel Behaviour after short circuit Wire break monitoring per channel | ||
Internal cycle time | 4 ms | ||
Fuse protection (short circuit) | Internal electronic fuse | ||
Intern power consumption nominal operating voltage | Typically 100 mA | ||
Basic error limit at 25 °C | ±0.5% | ||
Isolation channel - internal bus | Yes, without using the internal sensor supply | ||
Corrosion resistance class CRC | 1 - Low corrosion stress (when installed) | ||
Degree of protection | Dependent on the manifold block | ||
Product weight | 49 g | ||
Max. cable length | 30 m Shielded | ||
Material housing | PA-reinforced PC |