Dimensions (W x L x H) | 18.9 x 76.6 x 124.3 mm | ||
Number of inputs | 4 | ||
Diagnostics via bus | Measuring system error Short circuit/overload in sensor supply Parameter errors Monitoring of wire break Monitoring of zero pulse Tracking error monitoring | ||
Channel parameters | Signal extension | ||
Fuse protection (short circuit) | Internal electronic fuse per module | ||
Max. residual current of inputs per module | 1,8 A | ||
Power failure bridging | 10 ms | ||
Isolation channel - channel | no | ||
Permissible voltage fluctuations for electronics/sensors | ± 25% | ||
Power supply, connection type | Terminal strip | ||
Power supply, number of pins/wires | 6 | ||
Power supply, conductor diameter | 0,2 mm² ... 1,5 mm² | ||
Approval | RCM trademark c UL us listed (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Relative air humidity | 95 % Non-condensing | ||
Ambient temperature | -5 °C ... 50 °C | ||
Product weight | 88 g | ||
Max. address volume, inputs | 12 Byte | ||
Switching logic for inputs | PNP (positive switching) 2-wire sensors to IEC 61131-2 3-wire sensors to IEC 61131-2 | ||
Electrical connection input, connection type | 2x terminal strip | ||
Electrical connection input, number of connections/cores | 6 | ||
Electrical connection for input, conductor cross section | 0,2 mm² ... 1,5 mm² | ||
Electrical connection for input 2, function | Counting input | ||
Electrical connection for input 2, connection technology | Spring-loaded terminal | ||
Electrical connection for input 2, connection pattern | 995,848 | ||
Electrical connection for input 2, note on conductor cross section | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant |
Grid dimension | 18,9 mm | ||
Diagnostics via LED | Encoder supply error Errors per module Encoder error Encoder normal operation Encoder supply normal operation Status per channel | ||
Module parameters | Debounce time for digital inputs Pulse/zero pulse Integration time for speed measurement Internal revision ID Load value Latching event Latching signal Latching response Upper count limit Signal type/encoder type Signal evaluation Monitoring of cable break Monitoring of zero pulse Tracking error monitoring Lower count limit | ||
Input debounce time | 0.02 ms 0.1 ms 3 ms | ||
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 15 mA | ||
Nominal DC operating voltage, electronics/sensors | 24 V | ||
Isolation channel - internal bus | no | ||
Switching level | Signal 0: <= 5 V Signal 1: >= 11 V | ||
Power supply, function | Encoder supply | ||
power supply, connection system | Spring-loaded terminal | ||
Power supply, connection pattern | 995,844 | ||
Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves | ||
KC mark | KC-EMV | ||
Certificate issuing authority | UL E239998 | ||
Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 | ||
Storage temperature | -20 °C ... 70 °C | ||
Degree of protection | IP20 | ||
Note on ambient temperature | -5 - 60°C for vertical installation | ||
Max. address volume, outputs | 2 Byte | ||
Characteristic for inputs | To IEC 61131-2, type 3 | ||
Electrical connection input, function | Digital input | ||
Electrical connection input, connector system | Spring-loaded terminal | ||
Electrical connection input, connection pattern | 995,843 | ||
Electrical connection for input, note on conductor cross section | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves | ||
Electrical connection for input 2, connection type | Terminal strip | ||
Electrical connection for input 2, number of pins/wires | 6 | ||
Electrical connection for input 2, conductor cross section | 0,2 mm² ... 1,5 mm² | ||
Type of mounting | With H-rail | ||
Material housing | PA |