Dimensions (W x L x H) | 18.9 x 76.6 x 124.3 mm | ||
Diagnostics via LED | Errors per module Status per channel | ||
Module parameters | Short circuit diagnostics for actuator supply Deactivate sensor supply Behaviour after short circuit/overload | ||
Fuse protection (short circuit) | Internal electronic fuse, load per channel Internal electronic fuse, sensor for each module | ||
Intrinsic current consumption at nominal operating voltage load | Typically 15 mA | ||
Nominal operating voltage DC of load | 24 V | ||
Isolation channel - channel | no | ||
Permissible voltage fluctuation of load | ± 25 % | ||
power supply, connection system | Spring-loaded terminal | ||
Power supply, connection pattern | 995,847 | ||
Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves | ||
KC mark | KC-EMV | ||
Certificate issuing authority | UL E239998 | ||
Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 | ||
Storage temperature | -20 °C ... 70 °C | ||
Protection against direct and indirect contact | PELV | ||
Ambient temperature | -5 °C ... 50 °C | ||
Product weight | 96 g | ||
IO-Link, Protocol version | Master V 1.1 | ||
IO-Link, Port class | B | ||
IO-Link, Process data length OUT | Can be parameterised, 8-32 bytes | ||
IO-Link, Min. cycle time | Dependent on minimum supported cycle time of the connected IO-Link® device | ||
Electrical connection for IO-Link, connection type | 4x terminal strip | ||
Electrical connection for IO-Link, number of pins/wires | 6 | ||
Electrical connection for IO-Link, conductor cross section | 0,2 mm² ... 1,5 mm² | ||
Type of mounting | With H-rail | ||
Material housing | PA |
Grid dimension | 18,9 mm | ||
Diagnostics via bus | Device missing/failed Wire break Module error Short circuit Parameter errors Overflow/underflow Undervoltage General errors | ||
Channel parameters | Deactivate actuator supply Device error code Force channel x Channel mode Channel status Cycle time | ||
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 50 mA | ||
Nominal DC operating voltage, electronics/sensors | 24 V | ||
Isolation channel - internal bus | no | ||
Permissible voltage fluctuations for electronics/sensors | ± 25% | ||
Power supply, connection type | Terminal strip | ||
Power supply, number of pins/wires | 4 | ||
Power supply, conductor diameter | 0,2 mm² ... 1,5 mm² | ||
Approval | RCM trademark c UL us listed (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Relative air humidity | 95 % Non-condensing | ||
Degree of protection | IP20 | ||
Note on ambient temperature | -5 - 50 °C for horizontal installation | ||
Protocol | IO-Link® | ||
IO-Link, communication mode | Configurable via software SIO, COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd) | ||
IO-Link, Number of ports | 4 | ||
IO-Link, Process data length IN | Can be parameterised, 8-32 bytes | ||
IO-Link, communication | C/Q green LED | ||
Electrical connection for IO-Link, connection technology | Spring-loaded terminal | ||
Electrical connection for IO-Link, connection pattern | 995,843 | ||
Electrical connection for IO-Link, note on conductor cross section | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant |