Dimensions (W x L x H) | (incl. interlinking block) 50 x 107 x 50 mm | ||
Device-specific diagnostics | Channel-oriented and module-oriented diagnostics Undervoltage of modules Diagnostic memory | ||
Additional functions | Acyclic data access via PCP channel Channel-oriented diagnostics via fieldbus Start-up parameterisation in plain text via fieldbus System status can be mapped using process data Additional diagnostic interface for operator units | ||
Baud rate | 500, 2000 kbit/s | ||
Intern power consumption nominal operating voltage | Typ. 200 mA | ||
Corrosion resistance class CRC | 1 - Low corrosion stress | ||
Degree of protection | IP65 IP67 | ||
Product weight | 125 g | ||
Max. address volume, inputs | 12 Byte | ||
LED display, bus-specific | BA: Bus active RC: Remote bus check RD: Remote bus disable TR: Transmit/receive UL: Operating voltage | ||
Material housing | PA-reinforced PC |
Field bus interface | 2x Sub-D plug connector for self-assembly 2x M12x1, 5-pin, B-coded Socket and plug connector, Sub-D, 9-pin | ||
Parameterisation | Diagnostic behaviour Fail-safe response Forcing of channels Signal setup System parameter | ||
Operator controls | DIL switch | ||
Operational voltage range DC | 18 V ... 30 V | ||
Nominal operating voltage DC | 24 V | ||
Storage temperature | -20 °C ... 70 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Max. address volume, outputs | 12 Byte | ||
Protocol | Interbus | ||
LED display, product-specific | M: Modify, parameterisation PL: Load supply PS: Electronics supply, sensor supply SF: System fault |