Dimensions (W x L x H) | (incl. interlinking block and connection technology) 50 x 107 x 55 mm | ||
Diagnosis | Wire break per channel Short circuit/overload per channel Cross circuit Undervoltage of valves | ||
Safety function | Safely switching off supply voltage for the valves | ||
Performance Level (PL) | Safe switch-off/category 3, Performance Level e | ||
Fuse protection (short circuit) | Internal electronic fuse per channel | ||
Load capacity against FE | 400 nF | ||
Max. power supply per channel | 1.5 A | ||
Nominal operating voltage DC | 24 V | ||
Isolation channel - channel | no | ||
Voltage drop per channel | 0,6 V | ||
Approval | c UL us - Recognized (OL) | ||
Certificate issuing authority | German Technical Control Board (TÜV) Rheinland 01/205/5294.01/18 | ||
Storage temperature | -20 °C ... 70 °C | ||
Ambient temperature | -5 °C ... 50 °C | ||
Product weight | 50 g | ||
Note on outputs | 1 internal channel to switch off the valve voltage 2 external outputs | ||
Max. cable length | 200 m | ||
Note on materials | RoHS-compliant |
Number of outputs | 2 | ||
Parameterisation | Diagnostic behaviour Wire break monitoring per channel | ||
Safety Integrity Level (SIL) | Safe switch-off/SIL 3 | ||
LED display | 1 fail-safe mode protocol active 1 Group diagnostics 3 channel diagnostics 3 Channel status | ||
Intern power consumption nominal operating voltage | Typically 25 mA (power supply for electronics) Typ. 65 mA (load voltage supply for valve) | ||
Max. reaction time to switch-off command | F_WD_TIME + 23 ms | ||
Max. total current per module | 5 A | ||
Isolation channel - internal bus | Yes, with intermediate air supply | ||
Residual ripple | 2 Vpp within voltage range | ||
Permissible voltage fluctuations | -15%/+20% | ||
CE mark (see declaration of conformity) | To EC Machinery Directive | ||
Corrosion resistance class CRC | 1 - Low corrosion stress (when installed) | ||
Degree of protection | Dependent on the manifold block | ||
Note on ambient temperature | Observe derating curve for pneumatic interface | ||
Max. address volume, outputs | 6 Byte | ||
Max. address volume, inputs | 6 Byte | ||
Switching logic for outputs | P-M switching | ||
Material housing | PA-reinforced PC |