Stroke | 3 mm ... 2.000 mm | ||
Based on standard | ISO 15552 | ||
Mounting position | optional | ||
Position detection | Via proximity switch Without | ||
Mode of operation | Double-acting | ||
CE marking (see declaration of conformity) | To UK EX instructions | ||
ATEX category gas | II 2G | ||
Explosion ignition protection type for gas | Ex h IIC T4 Gb | ||
Explosion ambient temperature | -20°C <= Ta <= +60°C | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress 3 - high corrosion stress | ||
Impact energy in end positions | 5 J | ||
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke | 6.881 N ... 7.363 N | ||
Pneumatic connection | G1/2 | ||
Material cover | Die-cast aluminium Coated |
Piston diameter | 125 mm | ||
Cushioning | Elastic cushioning rings/plates at both ends Pneumatic cushioning, adjustable at both ends | ||
Design | Piston Piston rod Profile barrel | ||
Operating pressure | 0,6 bar ... 10 bar | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
ATEX category dust | II 2D | ||
Explosion ignition protection type for dust | Ex h IIIC T120°C Db | ||
Explosion protection certification outside the EU | EPL Db (GB) EPL Gb (GB) | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Ambient temperature | -40 °C ... 120 °C | ||
Theoretical force at 0.6 MPa (6 bar, 87 psi), return stroke | 6.881 N | ||
Type of mounting | Via female thread With accessories | ||
Note on materials | RoHS-compliant | ||
Material cylinder barrel | Wrought aluminium alloy Smooth anodised |