Specifications
Series (DRRD) | Semi-rotary drive, double piston |
---|---|
Size (32) | 32 |
Nominal swivel angle [°] (180) | 180 |
Output shaft (FH) | Flanged shaft, hollow |
Energy through-feed | None |
Cushioning (Y12) | Shock absorber, self-adjusting, linear at both ends, external |
Position sensing (A) | For proximity sensor |
EU certification | None |
---|---|
Intermediate position | None |
End-position locking | None |
Sensor mounting, external | None |
Version | Standard |
Operating instructions | With operating instructions |
Explosion ambient temperature | -10°C <= Ta <= +60°C | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Ambient temperature | -10 °C ... 60 °C | ||
Permissible mass moment of inertia | 0,15 kgm² ... 2,6 kgm² | ||
Pneumatic connection | G1/8 | ||
Material drive shaft | Tempered steel | ||
Material seals | NBR TPE-U(PU) | ||
Size | 32 | ||
Cushioning | Elastic cushioning rings/plates at both ends External hydraulic cushioning Internal hydraulic cushioning, soft Internal hydraulic cushioning normal | ||
Design | Rack and pinion | ||
Position detection | Via proximity switch | ||
Operating pressure | 2 bar ... 10 bar | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
Explosion protection certification outside the EU | EPL Db (GB) EPL Gb (GB) | ||
ATEX category gas | II 2G | ||
Explosion ignition protection type for gas | Ex h IIC T4 Gb |
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
LABS (PWIS) conformity | VDMA24364 zone III | ||
Theoretical torque at 0.6 MPa (6 bar, 87 psi) | 10,1 Nm | ||
Type of mounting | With through-hole Via female thread Either: | ||
Note on materials | RoHS-compliant | ||
Material cover | Wrought aluminium alloy Anodised | ||
Material housing | Wrought aluminium alloy Smooth anodised | ||
Swivel angle | 180 deg | ||
Mounting position | optional | ||
Max. number of intermediate positions | 1 | ||
Symbol | 00991265 | ||
Mode of operation | Double-acting | ||
CE marking (see declaration of conformity) | To UK EX instructions | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
ATEX category dust | II 2D | ||
Explosion ignition protection type for dust | Ex h IIIC T120°C Db |