Energy efficiency | ENEFF (CN) / Class 2 | ||
Mean time to failure (MTTF), subcomponent | 76 years, rotor position sensor 4469 years, holding brake | ||
Mass moment of inertia of brake | 1,082 kgcm² | ||
Operating voltage DC for brake | 24 V | ||
Rotor position transducer resolution | 19 bit | ||
Rotor position encoder interface | EnDat® 22 | ||
Permissible radial shaft load | 1.060 N | ||
Product weight | 17.000 g | ||
Phase-phase winding inductance | 13,44 mH | ||
Voltage constant, phase-to-phase | 162,39 mVmin | ||
Peak current | 20 A | ||
Nominal power rating of motor | 4.420 W | ||
Nominal rotary speed | 2.000 rpm | ||
Nominal torque | 20,05 Nm | ||
Number of pole pairs | 6 | ||
Nominal voltage DC | 565 V | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Low Voltage Directive In accordance with EU RoHS Directive | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Note on materials | RoHS-compliant | ||
Degree of protection | IP54 | ||
Rating class as per EN 60034-1 | S1 | ||
Conforms to standard | IEC 60034 | ||
Storage temperature | -20 °C ... 60 °C |
Mean time to dangerous failure (MTTFd), subcomponent | 152 years, rotor position sensor | ||
Switching cycles holding brake | 5 million idle actuations (without friction work!) | ||
Power consumption, brake | 15,6 W | ||
Brake holding torque | 18 Nm | ||
Rotor position sensor, encoder measuring principle | Inductive | ||
Rotor position sensor | Absolute multi-turn encoder | ||
Permissible axial shaft load | 200 N | ||
Total mass moment of inertia of output | 20,108 kgcm² | ||
Phase-phase winding resistance | 1,41 Ohm | ||
Motor constant | 2,72 Nm/A | ||
Nominal motor current | 7,8 A | ||
Max. rotational speed | 2.460 rpm | ||
Peak torque | 48,8 Nm | ||
Standstill torque | 25,48 Nm | ||
Type of winding switch | Star inside | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK regulations for electrical equipment To UK RoHS instructions | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Electrical connector system | Plug | ||
Temperature monitoring | PTC resistor | ||
Insulation protection class | F | ||
Relative air humidity | 0 - 90% | ||
Ambient temperature | -10 °C ... 40 °C |