Specifications
Series (HGPL) | Parallel gripper, sturdy with long stroke |
---|---|
Size (25) | 25 |
Stroke per gripper jaw [mm] (20) | 20 |
Position sensing (A) | For proximity sensor |
---|---|
Generation (B) | Function-optimised |
Material gripper jaws | Steel Hardened | ||
Stroke per gripper jaws | 20 mm | ||
Max. angular gripper jaw backlash ax, ay | < 0,2 deg | ||
Rotationally symmetrical | ≤ 0,2 mm | ||
Number of gripper jaws | 2 | ||
Mode of operation | Double-acting | ||
Design | Twin piston Guidance Piston gate valve T-shape Rack and pinion | ||
Symbol | 991,894 | ||
Total gripper force, closing, 0.6 MPa (6 bar, 87 psi) | 512 N | ||
Max. operating frequency of gripper | < 1 Hz | ||
Min. closing time at 0.6 MPa (6 bar, 87 psi) | 150 ms | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Gripper force per gripper jaw, opening, 0.6 MPa (6 bar, 87 psi) | 206 N | ||
Mass moment of inertia | 11,98 kgcm² | ||
Max. torque at gripper Mx static | 100 Nm | ||
Max. torque at gripper Mz static | 70 Nm | ||
Product weight | 1.015 g | ||
Pneumatic connection | M5 | ||
Material housing | Aluminium Smooth anodised |
Size | 25 | ||
Max. replacement accuracy | < 0,2 mm | ||
Max. gripper jaw backlash Sz | < 0,05 mm | ||
Repetition accuracy, gripper | < 0,03 mm | ||
Mounting position | optional | ||
Gripper function | Parallel | ||
Position detection | Via proximity switch | ||
Total gripper force, opening, 0.6 MPa (6 bar, 87 psi) | 412 N | ||
Operating pressure | 3 bar ... 8 bar | ||
Min. opening time at 0.6 MPa (6 bar, 87 psi) | 170 ms | ||
Max. mass per external gripper finger | 250 g | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Ambient temperature | 5 °C ... 60 °C | ||
Gripper force per gripper jaw, closing, 0.6 MPa (6 bar, 87 psi) | 256 N | ||
Max. force on gripper jaw Fz static | 1.500 N | ||
Max. torque at gripper My static | 60 Nm | ||
Lubrication interval for guide components | 5 MioCyc | ||
Type of mounting | Via female thread and centring sleeve Via through-hole and centring sleeve | ||
Note on materials | RoHS-compliant |