Valve function | 3/2-way, closed, monostable | ||
Standard nominal flow rate | 160 l/min | ||
Operating pressure | 0 bar ... 7 bar | ||
Type of reset | Mechanical spring | ||
Nominal size | 2,5 mm | ||
Manual override | Detenting | ||
Flow direction | Non-reversible | ||
Switching time off | 13 ms | ||
Duty cycle | 100% | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Storage temperature | -40 °C ... 100 °C | ||
Ambient temperature | -5 °C ... 40 °C | ||
Pneumatic connection, port 1 | G1/8 | ||
Pneumatic connection, port 3 | G1/8 |
Type of actuation | Electric | ||
pneumatic working port | G1/8 | ||
Design | Poppet valve with spring return | ||
Degree of protection | IP65 | ||
Sealing principle | Soft | ||
Type of piloting | Direct | ||
Symbol | 991,308 | ||
Switching time on | 12 ms | ||
Characteristic coil data | 110 V AC: 50/60 Hz, pick-up power 30.0 VA, holding power 22.0 VA 110 V DC: 12.7 W 120 V AC: 60 Hz, pick-up power 30.0 VA, holding power 22.0 VA 12 V AC: 50 Hz, pick-up power 30.0 VA, holding power 22.0 VA 12 V DC: 11.7 W 220 V AC: 50/60 Hz, pick-up power 30.0 VA, holding power 22.0 VA 220 V DC: 15.0 W 240 V AC: 50 Hz, pick-up power 30.0 VA, holding power 22.0 VA 240 V DC: 17.9 W 24 V AC: 50 Hz, pick-up power 30.0 VA, holding power 22.0 VA 24 V DC: 11.0 W 380 V AC: 50/60 Hz, pick-up power 30.0 VA, holding power 22.0 VA 42 V AC: 50/60 Hz, pick-up power 30.0 VA, holding power 22.0 VA 42 V DC: 12.0 W 48 V AC: 50 Hz, pick-up power 30.0 VA, holding power 22.0 VA 96 V DC: 11.0 W | ||
LABS (PWIS) conformity | VDMA24364-C1-L | ||
Media temperature | -10 °C ... 60 °C | ||
Type of mounting | With through-hole | ||
Pneumatic connection, port 2 | G1/8 | ||
Note on materials | RoHS-compliant |
Stock | 6 pcs. |
---|---|
Part number | 2199 |
Manufacturer | Festo |
Quantity | Unit Price |
---|---|
1 - 4 | $215.20 |
5+ | $210.89 |