Valve function | 2/2-way, closed, monostable | ||
Construction width | 10 mm | ||
pneumatic working port | Sub-base | ||
Operating pressure | 0,5 bar ... 6 bar | ||
Type of reset | Pneumatic spring | ||
Approval | RCM trademark | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Note on operation | Fixed power supply must be able to supply at least 1.7 A without voltage drop Do not operate without flow. For block mounting with flow, max. ambient temperature 45°C. | ||
Mounting position | optional | ||
Type of piloting | Direct | ||
Symbol | 992,259 | ||
Additional functions | Spark arresting Holding current reduction with energy recovery Safety shut-off | ||
C value | 0,4 l/sbar | ||
Switching time on 0.4 MPa (4 bar, 58 psi) and 24 V in new condition | 0,8 ms | ||
Switching time on 0.05 MPa (0.5 bar, 7.25 psi) and 24 V in new condition | 0,8 ms | ||
Switching time on 0.6 MPa (6 bar, 87 psi) and 24 V in new condition | 0,9 ms | ||
Tolerance switching time off | +15%/-25% | ||
Operational voltage range DC | 21,6 V ... 26,4 V | ||
Duty cycle | 100% | ||
Trigger signal voltage range DC | 3 V ... 30 V | ||
Permissible voltage fluctuations | +/- 10 % | ||
Note on operating and pilot medium | Lubricated operation not possible | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Storage temperature | -20 °C ... 50 °C | ||
Media temperature | -5 °C ... 60 °C | ||
Max. tightening torque for valve mounting | 0,7 Nm | ||
Electrical connection | 3-wire Cable | ||
Type of mounting | On sub-base | ||
Pneumatic connection, port 2 | Sub-base | ||
Material seals | HNBR | ||
Material cable sheath | PUR |
Type of actuation | Electric | ||
Standard nominal flow rate | 100 l/min | ||
Operating voltage | 24V DC | ||
Design | Poppet valve without spring return | ||
Degree of protection | IP55 | ||
KC mark | KC-EMV | ||
Grid dimension | 10,5 mm | ||
Sealing principle | Hard | ||
Manual override | None | ||
Flow direction | Non-reversible | ||
Reverse polarity protection | For operating voltage | ||
b value | 0,38 | ||
Max. switching frequency | 1.000 Hz | ||
Switching time off 0.4 MPa (4 bar, 58 psi) and 24 V in new condition | 0,4 ms | ||
Switching time off 0.05 MPa (0.5 bar, 7.25 psi) and 24 V in new condition | 0,5 ms | ||
Switching time off 0.6 MPa (6 bar, 87 psi) and 24 V in new condition | 0,4 ms | ||
Tolerance switching time on | +/-15% | ||
Input resistance | 34 kOhm | ||
Characteristic coil data | 24 V DC: low-current phase 2.0 W, high-current phase 7.0 W | ||
Note on input current | Linear rise 0.09-0.44 mA with a trigger signal of 3-15 V 0.44-15.44 mA with a trigger signal of 15-30 V | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Restrictions for environmental and media temperature | As a function of switching frequency (see graph) | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Permissible solenoid surface temperature | 120 °C | ||
Ambient temperature | -5 °C ... 60 °C | ||
Product weight | 75 g | ||
Cable length | 2,5 m | ||
Pneumatic connection, port 1 | Sub-base | ||
Note on materials | RoHS-compliant | ||
Material housing | PA-reinforced PPS reinforced | ||
Material screws | Steel |