Specifications
Series (MS) | MS series |
---|---|
Size (4) | Grid dimension 40 mm |
Function (EE) | On/off valve, electric |
Pneumatic connection (1/4) | Female thread G1/4 |
Supply voltage (10V24) | 24 V DC, 10 bar, connection pattern to EN 175301 |
Silencer (S) | Silencer |
Pressure gauge alternatives | None |
---|---|
Alternative pressure gauge scale | MS pressure gauge |
Type of mounting (WBM) | Mounting centrally at rear (wall mounting top), connecting plates not required |
EU certification | None |
UL certification | None |
Flow direction | Flow direction from left to right |
Operating pressure | 4 bar ... 14 bar | ||
ATEX category dust | II 3D | ||
Explosion ignition protection type for dust | Ex tc IIIC T105°C X Dc IP65 | ||
Suitable for use with food | See supplementary material information | ||
Mounting position | optional | ||
Product weight | 273 g | ||
Pilot air supply | Internal | ||
Material housing | Die-cast aluminium | ||
Type of actuation | Electric | ||
Manual override | Detenting None Non-detenting | ||
Type of piloting | Pilot actuated | ||
Pressure gauge (ANALOG) or Pressure display (DIGITAL) | Prepared for G1/4 Prepared for G1/8 Via pressure sensor With pressure gauge | ||
Duty cycle | 100% | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Media temperature | -10 °C ... 60 °C | ||
Ambient temperature | -10 °C ... 60 °C | ||
KC mark | KC-EMV | ||
Explosion protection | Zone 2 (ATEX) Zone 22 (ATEX) |
ATEX category gas | II 3G | ||
Explosion ignition protection type for gas | Ex nA IIC T4 X Gc | ||
Explosion ambient temperature | -10°C <= Ta <= +60°C | ||
Type of mounting | In-line installation With accessories Either: | ||
Flow direction | Non-reversible | ||
Pneumatic connection, port 3 | G1/4 | ||
Material seals | NBR | ||
Design | Piston gate valve | ||
Exhaust-air function | Without flow control option | ||
Type of reset | Mechanical spring | ||
Valve function | 3/2-way, closed, monostable | ||
Standard nominal flow rate | 1.000 l/min ... 2.000 l/min | ||
Characteristic coil data | 110 V AC: 50/60 Hz, pick-up power 3.0 VA, holding power 2.4 VA 230 V AC: 50/60 Hz, pick-up power 3.0 VA, holding power 2.4 VA 24 V DC: 1.8 W | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Note on materials | RoHS-compliant | ||
Degree of protection | IP65 | ||
Approval | c UL us - Recognized (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Explosion Protection Directive (ATEX) To EU Low Voltage Directive |