Mounting position | optional | ||
Duty cycle | 100% | ||
Characteristic coil data | 110 V AC: 50 Hz, pick-up power 7.5 VA, holding power 5.0 VA 110 V AC: 60 Hz, pick-up power 5.0 VA, holding power 3.7 VA 120 V AC: 60 Hz, pick-up power 5.0 VA, holding power 3.7 VA | ||
Maritime classification | See certificate | ||
CE marking (see declaration of conformity) | To UK regulations for electrical equipment | ||
Media temperature | -10 °C ... 50 °C | ||
Ambient temperature | -10 °C ... 50 °C | ||
Electrical connection | 3-pin Type A To DIN EN 175301-803 | ||
Material housing | PA | ||
Material winding | Copper |
Min. pick-up time | 10 ms | ||
Power factor (cos phi) | 0,7 | ||
Permissible voltage fluctuations | At 50 Hz ± 10% With 60 Hz -10...+20% | ||
CE mark (see declaration of conformity) | To EU Low Voltage Directive | ||
LABS (PWIS) conformity | VDMA24364-C1-L | ||
Degree of protection | IP65 | ||
Product weight | 80 g | ||
Type of mounting | Clamped Via retaining clamp With accessories | ||
Material electrical contact | Steel |