Nominal size, Laval nozzle | 0,95 mm | ||
Material keypad | PA-reinforced | ||
Material pins | Steel | ||
Material connector housing | Nickel-plated brass | ||
Material silencer | Wrought aluminium alloy PU foam | ||
Material housing | Die-cast aluminium PA-reinforced | ||
Material filter | Fabric PA Sintered steel | ||
Material seals | NBR | ||
Vacuum connection | QS-8 | ||
Pneumatic connection, port 1 | QS-8 | ||
Electrical connection | 5-pin M12x1 Plugs | ||
Reproducibility of switching values FS | 0,6 % | ||
Accuracy in ± % FS | 0,5 %FS | ||
Product weight | 321 g | ||
Ambient temperature | 0 °C ... 50 °C | ||
Degree of protection | IP65 | ||
Relative air humidity | 5 - 85 % | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Approval | RCM trademark c UL us listed (OL) | ||
Overload protection | Available | ||
Characteristic coil data | 24 V DC: low-current phase 0.3 W, high-current phase 2.55 W | ||
Switching output | PNP | ||
Max. output current | 100 mA | ||
Insulation voltage | 50 V | ||
Duty cycle | 100% | ||
Air supply time at nominal operating pressure | 0,2 s | ||
Nominal operating pressure | 6 bar | ||
Operating pressure for max. vacuum | 3,5 bar | ||
Setting range threshold value | -1 bar ... 0 bar | ||
Switching position indicator | LED | ||
Display type | LED | ||
Reverse polarity protection | For all electrical connections | ||
Symbol | 992,094 | ||
Switching element function | N/O contact | ||
Measured variable | Relative pressure | ||
Design | Modular | ||
Manual override | Non-detenting | ||
Ejector characteristic | High vacuum Standard | ||
Silencer design | Open |
Material fitting | Nickel-plated brass | ||
Material transmitter nozzle | Wrought aluminium alloy | ||
Material electrical contact | Gold-plated brass | ||
Material screws | Steel | ||
Material adjusting screw | Steel | ||
Material filter housing | PA-reinforced | ||
Material receiver nozzle | POM | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant | ||
Pneumatic connection, port 3 | Integrated silencer | ||
Type of mounting | With through-hole Via female thread With accessories | ||
Switching logic for inputs | PNP (positive switching) | ||
Hysteresis | 0,02 bar | ||
Pressure measuring range | -1 bar ... 0 bar | ||
Max. tightening torque | 0.8 Nm with female thread 2.5 Nm with through-hole | ||
Protection class | III | ||
Sound pressure level at nominal operating pressure | 73 dB(A) | ||
Media temperature | 0 °C ... 50 °C | ||
Note on operating and pilot medium | Lubricated operation not possible | ||
CE marking (see declaration of conformity) | To UK instructions for EMC | ||
KC mark | KC-EMV | ||
Pollution degree | 3 | ||
Immunity to surge | 0,8 kV | ||
Voltage drop | ≤ 1,5 V | ||
Off-state current | 0,1 mA | ||
No-load supply current | < 80 mA | ||
Inductive protective circuit | Adapted to MZ, MY, ME coils | ||
Operational voltage range DC | 20,4 V ... 27,6 V | ||
Max. suction flow rate against atmosphere | 19,5 l/min | ||
Max. vacuum | 93 % | ||
Operating pressure | 2 bar ... 8 bar | ||
Switching status indication | Optical | ||
Setting options | Teach-in | ||
Standard switching input | IEC 61131-2 | ||
Valve function | Closed | ||
Switching function | Threshold value comparator Threshold value with fixed hysteresis | ||
Measuring principle | Piezoresistive | ||
Short circuit current rating | yes | ||
Integrated function | Electric ejector pulse valve Flow control Electric on-off valve Filter Check valve Open silencer Vacuum switch | ||
Grade of filtration | 40 µm | ||
Mounting position | optional | ||
Grid dimension | 20 mm |