Specifications
Series (OVEM) | Vacuum generator |
---|---|
Nominal width of Laval nozzle (20) | 2.0 mm |
Vacuum type (H) | High vacuum |
Housing width (C) | 36 mm |
Pneumatic connections (QO) | Supply/vacuum port with QS fi ttings, exhaust port with open silencer |
Normal position of the vacuum generator (CE) | NC, normally closed (no vacuum generation) with ejector pulse |
---|---|
Electrical connection (N) | Plug M12 (5-pin) |
Vacuum sensor (LK) | IO-Link® |
Alternative vacuum display | Without |
Material receiver nozzle | POM | ||
Material screws | Steel | ||
Material connector housing | Nickel-plated brass | ||
Material pins | Steel | ||
Material keypad | TPE-U | ||
Nominal size, Laval nozzle | 2 mm | ||
Silencer design | Open | ||
Ejector characteristic | High vacuum Standard | ||
Manual override | Non-detenting Additionally via operating buttons | ||
Design | Modular | ||
Measured variable | Relative pressure | ||
Switching element function | N/C contact N/O contact | ||
Symbol | 992,094 | ||
Reverse polarity protection | For all electrical connections | ||
Display type | 4-place alphanumeric Back-lit LCD | ||
Displayable units | bar | ||
Setting options | IO-Link® Via display and keys | ||
Switching status indication | Optical | ||
Operating pressure | 2 bar ... 8 bar | ||
Max. vacuum | 93 % | ||
Max. suction flow rate against atmosphere | 98 l/min | ||
Operational voltage range DC | 20,4 V ... 27,6 V | ||
Insulation voltage | 50 V | ||
Max. output current | 100 mA | ||
Switching output | 2xPNP | ||
Characteristic coil data | 24 V DC: low-current phase 0.3 W, high-current phase 2.55 W | ||
Overload protection | Available | ||
Approval | RCM trademark c UL us listed (OL) | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Relative air humidity | 5 - 85 % | ||
Degree of protection | IP65 | ||
Ambient temperature | 0 °C ... 50 °C | ||
Product weight | 825 g | ||
Accuracy in ± % FS | 3 %FS | ||
Protocol | IO-Link® | ||
IO-Link, Profile | Smart sensor profile | ||
IO-Link, communication mode | COM2 (38.4 kBaud) | ||
IO-Link, Process data length OUT | 1 bytes | ||
IO-Link, Process data length IN | 2 bytes | ||
IO-Link, Min. cycle time | 3.5 ms | ||
IO-Link, Device ID | 0x00003E | ||
Protection against tampering | Electronic interlock | ||
Pneumatic connection, port 1 | QS-10 | ||
Vacuum connection | QS-12 | ||
Material seals | HNBR NBR | ||
Material filter housing | PA-reinforced | ||
Material adjusting screw | Steel |
Material silencer | Wrought aluminium alloy POM PU foam | ||
Material screen | PA | ||
Material electrical contact | Gold-plated brass | ||
Material transmitter nozzle | Wrought aluminium alloy | ||
Material fitting | Nickel-plated brass | ||
Grid dimension | 36 mm | ||
Mounting position | optional | ||
Grade of filtration | 40 µm | ||
Integrated function | Electric ejector pulse valve Flow control Electric on-off valve Filter Air saving function, electrical Check valve Open silencer Vacuum switch | ||
Short circuit current rating | yes | ||
Measuring principle | Piezoresistive | ||
Switching function | Window comparator Threshold value comparator | ||
Valve function | Closed | ||
Standard switching input | IEC 61131-2 | ||
Indicating range | -0,999 bar ... 0 bar | ||
Setting range hysteresis | -0,9 bar ... 0 bar | ||
Switching position indicator | LCD | ||
Setting range threshold value | -0,999 bar ... 0 bar | ||
Operating pressure for max. vacuum | 4 bar | ||
Nominal operating pressure | 6 bar | ||
Air supply time at nominal operating pressure | 0,2 s | ||
Duty cycle | 100% | ||
No-load supply current | < 70 mA | ||
Off-state current | 0,1 mA | ||
Voltage drop | ≤ 1,8 V | ||
Immunity to surge | 0,8 kV | ||
Pollution degree | 3 | ||
KC mark | KC-EMV | ||
CE marking (see declaration of conformity) | To UK instructions for EMC | ||
Note on operating and pilot medium | Lubricated operation not possible | ||
Media temperature | 0 °C ... 50 °C | ||
Sound pressure level at nominal operating pressure | 62 dB(A) | ||
Protection class | III | ||
Max. tightening torque | 0.8 Nm with female thread 2.5 Nm with through-hole | ||
Pressure measuring range | -1 bar ... 0 bar | ||
Reproducibility of switching values FS | 0,6 % | ||
IO-Link, Protocol version | Device V 1.1 | ||
IO-Link, Function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | ||
IO-Link, Port class | A | ||
IO-Link, Process data content OUT | 1 bit (ejector pulse IN/OUT) 1 bit (vacuum ON/OFF) | ||
IO-Link, Process data content IN | 14 bit PDV (pressure measurement value) 2 bit BDC (pressure monitoring) | ||
IO-Link, Data storage required | 500 Byte | ||
Electrical connection | 5-pin M12x1 Plugs | ||
Type of mounting | With through-hole Via female thread With accessories | ||
Pneumatic connection, port 3 | Silencer | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant | ||
Material filter | Fabric PA Sintered steel | ||
Material housing | Wrought aluminium alloy PA-reinforced |