Conforms to standard | EN 60947-5-1 | ||
CE mark (see declaration of conformity) | To EU Low Voltage Directive | ||
Measured variable | Relative pressure | ||
Operating pressure | 0 bar ... 1 bar | ||
Note on operating and pilot medium | Lubricated operation not possible | ||
Switching output | Contacting | ||
Switching element function | Changeover switch | ||
Switch-off point | 0,05 bar | ||
Max. switching output voltage DC | 250 V | ||
Utilisation category - resistive load | AC-12 DC-12 | ||
Electrical connection 1, connection type | Cable | ||
Cable length | 1 m | ||
Type of mounting | With through-hole | ||
Pneumatic connection | M5 | ||
Material housing | Die-cast aluminium Anodised aluminium | ||
Degree of protection | IP62 | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Symbol | 991,470 | ||
CE marking (see declaration of conformity) | To UK regulations for electrical equipment | ||
Measurement method | Pneumatic/electric pressure transducer | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:-:-] | ||
Ambient temperature | -10 °C ... 50 °C | ||
Switching function | Threshold value with fixed hysteresis | ||
Switch-on point | 0,05 bar | ||
Max. switching output voltage AC | 250 V | ||
Utilisation category - inductive load | AC-14 DC-13 | ||
Electrical connection | 4-wire Cable | ||
Electrical connection 1, connector system | Open end | ||
Material cable sheath | PVC | ||
Mounting position | optional | ||
Product weight | 230 g | ||
Setting options | Permanently set | ||
Insulation voltage | 2.000 V | ||
Pollution degree | 3 |