Material membrane | CR | ||
Symbol | 995,409 | ||
CE marking (see declaration of conformity) | To UK regulations for electrical equipment | ||
Measurement method | Pneumatic/electric pressure transducer | ||
Max. overload pressure | 8 bar | ||
Note on operating and pilot medium | Lubricated operation possible | ||
Ambient temperature | 0 °C ... 60 °C | ||
Switching function | Threshold value with fixed hysteresis | ||
Switch-on point max. | 0,25 bar | ||
Max. switching frequency | 1 Hz | ||
Operational voltage range AC | 12 V ... 250 V | ||
Utilisation category - inductive load | AC-14 DC-13 | ||
Electrical connection | 3 connector leads | ||
Cable length | 0,5 m | ||
Type of mounting | On 1n mounting frame With through-hole Either: | ||
Pneumatic connection | PK-4 | ||
Material housing | PA-reinforced POM Steel VMQ (silicone) | ||
Material electrical connection | Tin-plated | ||
Degree of protection | IP67 | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L |
Conforms to standard | EN 60947-5-1 | ||
CE mark (see declaration of conformity) | To EU Low Voltage Directive | ||
Measured variable | Relative pressure | ||
Operating pressure | 0 bar ... 0,25 bar | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Media temperature | 0 °C ... 60 °C | ||
Switching output | Contacting | ||
Switching element function | Changeover switch | ||
Switch-off point min. | 0,07 bar | ||
Min. load current | 100 mA | ||
Operational voltage range DC | 12 V ... 250 V | ||
Utilisation category - resistive load | AC-12 DC-12 | ||
Electrical connection 1, connector system | Open end | ||
Material cable sheath | PVC | ||
Mounting position | optional | ||
Product weight | 40 g | ||
Material switch contact | Silver | ||
Setting options | Permanently set | ||
Insulation voltage | 2.000 V | ||
Pollution degree | 3 |