Design | Mechanical sequence counter with pneumatic drive | ||
Display | 6-digit | ||
Drop-off pressure reset | < 0.15 bar | ||
Response pressure reset | 2 bar | ||
Min. reset pressure | 2 bar | ||
Min. pulse length reset | 150 ms | ||
Min. pause period reset | 50 ms | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Ambient temperature | 0 °C ... 60 °C | ||
Type of mounting | Front panel mounting | ||
Material housing | PA |
Type of reset | Pushbutton or pneumatic signal | ||
Drop-off pressure drive | < 0.15 bar | ||
Response pressure drive | > 0.8 bar | ||
Operating pressure | 2 bar ... 8 bar | ||
Min. pulse length drive | 8 ms | ||
Min. pause period drive | 10 ms | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
Note on operating and pilot medium | Lubricated operation possible | ||
Product weight | 70 g | ||
Pneumatic connection | M5 |