repeatability (% of full scale value) | ± 1 % | ||
Type | with sensor element based on piezo resistance | ||
output signal digital | 2 x pnp | ||
operating pressure min | 0 bar | ||
compressed air connection type | flange with o-ring | ||
working pressure min. | 0 bar | ||
min. ambient temperature | 0 °c | ||
min. medium temperature | 0 °c | ||
Medium | compressed air | ||
measurement | relative pressure | ||
switching logic | no (make contact) | ||
protection against overpressure | 15 bar | ||
Vibration resistance | 10 - 55 hz, 0,1 mm |
function | 2 x pnp | ||
mounting orientation | l (horizontal) | ||
precision (% of full scale value) | ± 3 % | ||
operating pressure max | 10 bar | ||
compressed air connection | Ø 1,2x1 | ||
working pressure max | 10 bar | ||
max. ambient temperature | 60 °c | ||
max. medium temperature | 50 °c | ||
oil content of compressed air max. | 1 mg/m³ | ||
Display | led | ||
operating pressure display | 2 led | ||
shock resistance max. | 10 g |