Specifications
Series (SDE5) | Pressure sensor |
---|---|
Pressure measuring range (D10) | 0 ... 10 bar |
Pressure inlet | Relative pressure |
Output function (O3) | Window comparator with fixed hysteresis, N/O contact |
Pneumatic connection (Q6E) | Push-in connector 6 mm, at one end |
---|---|
Electrical output 1 (P) | PNP |
Electrical connection (K) | Open end |
Measurement method | Piezoresistive pressure sensor | ||
Pneumatic connection | QS-6 | ||
Material housing | PA POM | ||
Setting range threshold value | 0 % ... 100 % | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Symbol | 991,887 | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Note on materials | RoHS-compliant | ||
Start value for pressure measuring range | 0 bar | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Media temperature | 0 °C ... 50 °C | ||
Repetition accuracy in ± %FS | 0,3 %FS | ||
Switching output | PNP | ||
Switching element function | N/O contact | ||
Short circuit current rating | yes | ||
Reverse polarity protection | For all electrical connections | ||
Cable length | 2,5 m |
Mounting position | optional | ||
Product weight | 47 g | ||
Switching status indication | Yellow LED | ||
Degree of protection | IP40 | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Measured variable | Relative pressure | ||
End value for pressure measuring range | 10 bar | ||
Note on operating and pilot medium | Lubricated operation possible | ||
Ambient temperature | 0 °C ... 50 °C | ||
Temperature coefficient in ± %FS/K | 0,05 %FS/K | ||
Switching function | Window comparator | ||
Max. output current | 100 mA | ||
Operational voltage range DC | 15 V ... 30 V | ||
Electrical connection | 3-wire Cable To EN 60947-5-2 | ||
Type of mounting | With accessories |