Specifications

Weight Pneumatic connection Mounting Position Operating Pressure
160g For tubing O.D. 12 mm optional 0 MPa ... 1 MPa
Symbol 992,243
Corrosion resistance class CRC 2 - Moderate corrosion stress
Pressure drop < 100 mbar
Protection against tampering PIN code
Displayable units l l/min m3 scf scfm
Material housing PA-reinforced
Pneumatic connection For tubing O.D. 12 mm
Type of mounting With through-hole With H-rail
Electrical connection 1, number of connections/cores 5
Electrical connection 1, connection type Plugs
No-load supply current 120 mA
Overload protection Available
Max. load resistance current output 500 Ohm
Output characteristic curve starting value 4 mA
Flow characteristic curve start value 0 l/min
Max. output current 100 mA
Switching function Window comparator Threshold value comparator
Pressure influence span in ± %FS/bar 0,5 %FS/b.
Repetition accuracy span in ± %FS 0,8 %FS
Accuracy of flow rate ± (3% o.m.v. + 0.3% FS)
Ambient temperature 0 °C ... 50 °C
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4] Nitrogen
Temperature measurement end value 50 °C
End value for flow rate measuring range 1.000 l/min
Measurement method Heat Loss
Flow direction Unidirectional P1 -> P2
Note on materials RoHS-compliant
Explosion ambient temperature 0°C <= Ta <= +50°C
ATEX category dust II 3D
ATEX category gas II 3G
CE marking (see declaration of conformity) To UK instructions for EMC To UK RoHS instructions
Approval RCM trademark c UL us - Recognized (OL)
LABS (PWIS) conformity VDMA24364-B1/B2-L
Protection class III
Degree of protection IP65
Setting options Teach-in Via display and keys
Display type Illuminated LCD, multi-colour
Product weight 160 g
Mounting position optional
Electrical connection 1, connection pattern 995,383
Electrical connection 1, connector system M12x1, A-coded to EN 61076-2-101
Reverse polarity protection For all electrical connections
Operational voltage range DC 15 V ... 30 V
Short circuit current rating yes
Output characteristic curve end value 20 mA
Flow characteristic curve end value 1.000 l/min
Analogue output 4 - 20 mA
Switching element function N/C or N/O contact, switchable
Switching output 2 x PNP or 2 x NPN, switchable
Temperature coefficient span in ± %FS/K Typ. 0.1%FS/K
Repetition accuracy offset in ± %FS 0,2 %FS
Nominal temperature 23 °C
Media temperature 0 °C ... 50 °C
Operating pressure 0 MPa ... 1 MPa
Temperature measurement start value 0 °C
Start value for flow rate measuring range 10 l/min
Measuring principle Thermal
Measured variable Volume Volumetric flow rate
Certificate issuing authority UL E322346
Explosion ignition protection type for dust Ex tc IIIB T80°C X Dc IP54
Explosion ignition protection type for gas Ex nA IIC T5 X Gc
Explosion protection Zone 2 (ATEX) Zone 22 (ATEX)
CE mark (see declaration of conformity) To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive