Specifications
Series (SFAH) | Flow sensor |
---|---|
Flow measuring range (50) | Max. 50 l/min |
Flow rate input (U) | Unidirectional |
Pneumatic connection (Q6) | Push-in connector 6 mm |
Thread type | None |
Outlet orientation (AR) | Angled, adjustable |
Electrical output 1 (PNLK) | PNP/NPN/IO-Link |
Electrical output 2 (PNVBA) | PNP or NPN or 0 ... 10 V or 1 ... 5 V or 4 ... 20 mA |
---|---|
Electrical connection (M8) | Plug M8, A-coded |
Mounting accessories | None |
Electrical accessories | None |
Protective devices | None |
Certifi cate | None |
Nominal temperature | 23 °C | ||
Pneumatic connection, outlet direction | Angled, adjustable | ||
Material housing | PA-reinforced | ||
Display type | Illuminated LCD, multi-colour | ||
Setting options | IO-Link® Teach-in Via display and keys | ||
Degree of protection | IP40 | ||
Protection class | III | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Approval | RCM trademark c UL us listed (OL) | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Note on materials | RoHS-compliant | ||
Flow direction | Unidirectional | ||
Measurement method | Heat transfer | ||
End value for flow rate measuring range | 50 l/min | ||
Operating medium | Argon Compressed air to ISO 8573-1:2010 [6:4:4] Nitrogen | ||
Ambient temperature | 0 °C ... 50 °C | ||
Repetition accuracy offset in ± %FS | 0,2 %FS | ||
Temperature coefficient span in ± %FS/K | Typ. 0.15%FS/K | ||
Switching output | 2 x PNP or 2 x NPN, switchable | ||
Switching element function | N/C or N/O contact, switchable | ||
Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V | ||
Flow characteristic curve end value | 50 l/min | ||
Min. load resistance voltage output | 20 kOhm | ||
Overload protection | Available | ||
IO-Link, Protocol version | Device V 1.1 | ||
IO-Link, Function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | ||
IO-Link, SIO-Mode support | Yes | ||
IO-Link, Process data length IN | 3 bytes | ||
IO-Link, Service data IN | 32-bit volume/mass measurement | ||
IO-Link, Data storage required | < 500 Byte | ||
No-load supply current | ≤ 25 mA | ||
Electrical connection 1, connection type | Plugs | ||
Electrical connection 1, number of connections/cores | 4 | ||
Type of mounting | With accessories |
Pneumatic connection | For tubing O.D. 6 mm | ||
Product weight | 60 g | ||
Material in contact with the medium | Anodised wrought aluminium alloy Epoxy NBR PA-reinforced Silicon Silicon nitride High-alloy stainless steel | ||
Displayable units | g g/min l l/min scft scft/h scft/min | ||
Protection against tampering | IO-Link PIN code | ||
Pressure drop | 12 mbar | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Symbol | 995,794 | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Certificate issuing authority | UL E322346 | ||
Measured variable | Mass flow rate Volumetric flow rate | ||
Measuring principle | Thermal | ||
Start value for flow rate measuring range | 1 l/min | ||
Operating pressure | -0,9 bar ... 10 bar | ||
Media temperature | 0 °C ... 50 °C | ||
Accuracy of flow rate | ± (2% o.m.v. + 1% FS) | ||
Repetition accuracy span in ± %FS | 0,8 %FS | ||
Pressure influence span in ± %FS/bar | 1 %FS/b. | ||
Switching function | Window comparator Threshold value comparator Auto difference monitoring | ||
Max. output current | 100 mA | ||
Flow characteristic curve start value | 0 l/min | ||
Max. load resistance current output | 500 Ohm | ||
Short circuit current rating | yes | ||
Protocol | IO-Link® | ||
IO-Link, Profile | Smart sensor profile | ||
IO-Link, communication mode | COM2 (38.4 kBaud) | ||
IO-Link, Port class | A | ||
IO-Link, Process data content IN | 1 bit BDC (volume monitoring) 14 bit PDV (measured flow value) 2 bit BDC (flow monitoring) | ||
IO-Link, Min. cycle time | 4 ms | ||
Operational voltage range DC | 22 V ... 26 V | ||
Reverse polarity protection | For all electrical connections | ||
Electrical connection 1, connector system | M8x1, A-coded, to EN 61076-2-104 | ||
Electrical connection 1, connection pattern | 991,171 | ||
Mounting position | optional |