Specifications

Weight Mounting Position Operating Pressure
400g optional 0 bar ... 12 bar
Symbol 995,566
Corrosion resistance class CRC 3 - high corrosion stress
Displayable units US gal US gal/min cft cft/min l l/h l/min m3 °C °F
Material housing PA-reinforced
Fluid connection Female thread G1/2
Max. cable length 20 m with IO-Link® operation 30 m
Electrical connection 1, type of mounting Screw-type lock
Electrical connection 1, connector system M12x1, A-coded to EN 61076-2-101
Reverse polarity protection For all electrical connections
IO-Link, Data storage required 500 Byte
IO-Link, Service data IN 32-bit volume measurement
IO-Link, Process data length IN 3 bytes
IO-Link, Port class A
IO-Link, communication mode COM2 (38.4 kBaud)
IO-Link, Profile Smart sensor profile
Protocol IO-Link®
Short circuit current rating yes
Max. load resistance current output 500 Ohm
Flow characteristic curve start value 0 l/min
Max. output current 100 mA
Switching function Window comparator Threshold value comparator Freely programmable
Temperature coefficient span in ± %FS/K Typ. ± 0.05%FS/K
Accuracy temperature in ± °C 2 °C
Nominal temperature 23 °C
Media temperature 0 °C ... 90 °C
Operating medium Liquid media Water Neutral fluids
Operating pressure 0 bar ... 12 bar
Start value for flow rate measuring range 1,8 l/min
Flow direction Unidirectional P1 -> P2
Note on materials RoHS-compliant
CE mark (see declaration of conformity) To EU EMC Directive In accordance with EU RoHS Directive
LABS (PWIS) conformity VDMA24364-B2-L
Degree of protection IP65
Material in contact with the medium EPDM (peroxide) ETFE Stainless steel PA6T/6I reinforced
Product weight 400 g
Mounting position optional
Electrical connection 1, connection pattern 995,383
Electrical connection 1, number of connections/cores 5
Electrical connection 1, connection type Plugs
Operational voltage range DC 18 V ... 30 V
IO-Link, Min. cycle time 5 ms
IO-Link, Process data content IN 1 bit BDC (volume monitoring) 14 bit PDV (measured flow value) 2 bit BDC (flow monitoring)
IO-Link, Process data length OUT 0 bytes
IO-Link, SIO-Mode support Yes
IO-Link, Function classes Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel
IO-Link, Protocol version Device V 1.1
Overload protection Available
Min. load resistance voltage output 15 kOhm
Flow characteristic curve end value 32 l/min
Analogue output 0 - 10 V 4 - 20 mA 1 - 5 V
Switching element function N/C or N/O contact, switchable
Switching output 2 x PNP or 2 x NPN, switchable
Repetition accuracy of flow rate < ± 0.5% FS for flow rate <= 50% FS < ± 1% o.m.v. for flow rate >= 50% FS
Accuracy of flow rate ± 2% FS for flow rate <= 50% FS ± 3% of measured value for flow rate >= 50% FS
Ambient temperature 0 °C ... 50 °C
Note on operating and pilot medium Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances in contact with the media must be ensured.
Note on operating pressure Max. 12 bar at 40°C Max. 6 bar at 100°C
End value for flow rate measuring range 32 l/min
Measurement method Flow: Vortex Temperature: PT1000
Measured variable Flow rate Temperature
CE marking (see declaration of conformity) To UK instructions for EMC To UK RoHS instructions
Approval RCM trademark c UL us listed (OL)
$582.94
Stock 2 pcs.
Part number 8036871
Manufacturer Festo
Quantity Unit Price
1+ $582.94
  • Open Registration
    Create your account instantly
  • Support 24/7
    Ask us anytime
  • 100% Safety
    Only secure payments: bank transfer, credit card and PayPal
  • Volume Discounts
    Optimize your supplies