Symbol | 995,566 | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Note on materials | RoHS-compliant | ||
Flow direction | Unidirectional P1 -> P2 | ||
Start value for flow rate measuring range | 1,8 l/min | ||
Temperature measurement start value | 0 °C | ||
Operating pressure | 0 bar ... 12 bar | ||
Operating medium | Liquid media Water Neutral fluids | ||
Media temperature | 0 °C ... 90 °C | ||
Nominal temperature | 23 °C | ||
Accuracy temperature in ± °C | 2 °C | ||
Temperature coefficient span in ± %FS/K | Typ. ± 0.05%FS/K | ||
Switching function | Window comparator Threshold value comparator Freely programmable | ||
Max. output current | 100 mA | ||
Flow characteristic curve start value | 0 l/min | ||
Temperature characteristic curve start value | 0 °C | ||
Max. load resistance current output | 500 Ohm | ||
Short circuit current rating | yes | ||
Protocol | IO-Link® | ||
IO-Link, Profile | Smart sensor profile | ||
IO-Link, communication mode | COM2 (38.4 kBaud) | ||
IO-Link, Port class | A | ||
IO-Link, Process data length IN | 5 bytes | ||
IO-Link, Service data IN | 32-bit volume measurement | ||
IO-Link, Data storage required | 500 Byte | ||
Reverse polarity protection | For all electrical connections | ||
Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 | ||
Electrical connection 1, type of mounting | Screw-type lock | ||
Max. cable length | 20 m with IO-Link® operation 30 m | ||
Fluid connection | Female thread G1/2 | ||
Material housing | PA-reinforced | ||
Displayable units | US gal US gal/min cft cft/min l l/h l/min m3 °C °F | ||
Corrosion resistance class CRC | 3 - high corrosion stress |
Approval | RCM trademark c UL us listed (OL) | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Measured variable | Flow rate Temperature | ||
Measurement method | Flow: Vortex Temperature: PT1000 | ||
End value for flow rate measuring range | 32 l/min | ||
Temperature measurement end value | 90 °C | ||
Note on operating pressure | Max. 12 bar at 40°C Max. 6 bar at 100°C | ||
Note on operating and pilot medium | Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances in contact with the media must be ensured. | ||
Ambient temperature | 0 °C ... 50 °C | ||
Accuracy of flow rate | ± 2% FS for flow rate <= 50% FS ± 3% of measured value for flow rate >= 50% FS | ||
Repetition accuracy of flow rate | < ± 0.5% FS for flow rate <= 50% FS < ± 1% o.m.v. for flow rate >= 50% FS | ||
Switching output | 2 x PNP or 2 x NPN, switchable | ||
Switching element function | N/C or N/O contact, switchable | ||
Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V | ||
Flow characteristic curve end value | 32 l/min | ||
Temperature characteristic curve end value | 100 °C | ||
Min. load resistance voltage output | 15 kOhm | ||
Overload protection | Available | ||
IO-Link, Protocol version | Device V 1.1 | ||
IO-Link, Function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | ||
IO-Link, SIO-Mode support | Yes | ||
IO-Link, Process data length OUT | 0 bytes | ||
IO-Link, Process data content IN | 1 bit BDC (temperature monitoring) 1 bit BDC (volume monitoring) 14 bit PDV (measured flow value) 14 bit PDV (measured temperature value) 2 bit BDC (flow monitoring) | ||
IO-Link, Min. cycle time | 5 ms | ||
Operational voltage range DC | 18 V ... 30 V | ||
Electrical connection 1, connection type | Plugs | ||
Electrical connection 1, number of connections/cores | 5 | ||
Electrical connection 1, connection pattern | 995,383 | ||
Mounting position | optional | ||
Product weight | 400 g | ||
Material in contact with the medium | EPDM (peroxide) ETFE Stainless steel PA6T/6I reinforced | ||
Degree of protection | IP65 | ||
LABS (PWIS) conformity | VDMA24364-B2-L |