Setting options | IO-Link® Potentiometer Teach-in | ||
Immunity to surge | 1 kV | ||
Pollution degree | 3 | ||
Conforms to standard | EN 60947-5-2 | ||
Approval | RCM trademark c UL us listed (OL) | ||
Certificate issuing authority | UL E232949 | ||
Measuring principle | Optoelectronic | ||
Type of light | Red LED | ||
Operating distance | 2 mm ... 1.000 mm | ||
Reference material | Standard white 90%, 100x100 mm | ||
Switching element function | Switchable PNP, light switching NPN, dark switching | ||
Max. switching frequency | 1.000 Hz | ||
Voltage drop | 0 V ... 1,5 V | ||
Short circuit current rating | Pulsed | ||
IO-Link, Protocol version | Device V 1.1 | ||
IO-Link, SIO-Mode support | Yes | ||
IO-Link, Process data length OUT | 2 bit | ||
IO-Link, Process data length IN | 1 bit | ||
IO-Link, Min. cycle time | 2.3 ms | ||
Operational voltage range DC | 10 V ... 30 V | ||
No-load supply current | 25 mA | ||
Electrical connection 1, connection type | Plugs | ||
Electrical connection 1, number of connections/cores | 3 | ||
Electrical connection 1, connection pattern | 991,155 | ||
Type of mounting | Via through-hole for M3 screw | ||
Mounting position | optional | ||
Material housing | PC PMMA | ||
Switching status indication | Yellow LED | ||
Setting range upper limit | 1.000 mm |
Insulation voltage | 500 V | ||
Corrosion resistance class CRC | 1 - Low corrosion stress | ||
Design | Block design | ||
Symbol | 995,956 | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant | ||
Detection method | Diffuse sensor | ||
Max. light spot | 65 mm at a sensing range of 1000 mm | ||
Ambient temperature | -40 °C ... 60 °C | ||
Switching output | Push-pull | ||
Hysteresis | 200 mm | ||
Max. output current | 100 mA | ||
Timer function | Via IO-Link® | ||
Protocol | IO-Link® | ||
IO-Link, communication mode | COM2 (38.4 kBaud) | ||
IO-Link, Port class | A | ||
IO-Link, Process data content OUT | 1 bit (emitter disable) 1 bit (Hold) | ||
IO-Link, Process data content IN | 1 bit SSC (switching signal) | ||
IO-Link, Data storage required | 2.000 Byte | ||
Residual ripple | 10 % | ||
Reverse polarity protection | For all electrical connections | ||
Electrical connection 1, connector system | M8x1, A-coded, to EN 61076-2-104 | ||
Electrical connection 1, type of mounting | Screw-type lock | ||
Material electrical contact | Gold-plated brass | ||
Tightening torque | 0,8 Nm | ||
Product weight | 10 g | ||
Ready status indication | Green LED | ||
Setting range lower limit | 75 mm | ||
Degree of protection | IP65 IP67 IP69K |