Symbol | 997,316 | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Protection against tampering | Electronic interlock | ||
Display type | Illuminated LCD, multi-colour | ||
Product weight | 510 g | ||
Type of mounting | With through-hole With H-rail Either: | ||
Electrical connection 1, type of mounting | Screw-type lock | ||
Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 | ||
Reverse polarity protection | For all electrical connections | ||
IO-Link, Data storage required | < 500 Byte | ||
IO-Link, Service data IN | 14-bit supply pressure | ||
IO-Link, Process data length IN | 2 bytes | ||
IO-Link, Port class | A | ||
IO-Link, communication mode | COM2 (38.4 kBaud) | ||
IO-Link, Profile | Smart sensor profile | ||
Protocol | IO-Link® | ||
Max. load resistance current output | 500 Ohm | ||
End value of distance characteristic | 300 µm | ||
Analogue output | 4 - 20 mA | ||
Switching element function | N/C or N/O contact, switchable | ||
Switching output | PNP/NPN, switchable | ||
Ambient temperature | 0 °C ... 50 °C | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Operating pressure | 4 bar ... 7 bar | ||
Measuring principle | Pneumatic | ||
Note on materials | RoHS-compliant | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Approval | RCM trademark c UL us - Recognized (OL) |
LABS (PWIS) conformity | VDMA24364-C1-L | ||
Degree of protection | IP65 | ||
Setting options | IO-Link® Teach-in Via display and keys | ||
Material housing | PA-reinforced | ||
Pneumatic connection | QS-6 | ||
Electrical connection 1, connection pattern | 991,172 | ||
Electrical connection 1, number of connections/cores | 5 | ||
Electrical connection 1, connection type | Plugs | ||
Operational voltage range DC | 22,8 V ... 26,4 V | ||
IO-Link, Min. cycle time | 3 ms | ||
IO-Link, Process data content IN | 2-bit SSC (distance monitoring) 1-bit SSC (supply pressure monitoring) 10-bit PDV (distance) | ||
IO-Link, Process data length OUT | 0 bytes | ||
IO-Link, SIO-Mode support | Yes | ||
IO-Link, Function classes | Process data variable (PDV) Identification Diagnostics Teach channel Switching signal channel (SSC) | ||
IO-Link, Protocol version | Device V 1.1 | ||
Short circuit current rating | yes | ||
Rise time | 22 ms | ||
Starting value of distance characteristic | 0 µm | ||
Max. output current | 100 mA | ||
Switching function | Window comparator Threshold value with variable hysteresis | ||
Repetition accuracy in ± µm | 2,5 µm | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Supply pressure | 0,8 bar ... 1,6 bar | ||
Sensing range | 20 µm ... 200 µm | ||
Detected variable | Distance | ||
KC mark | KC-EMV | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive |