Symbol | 992,257 | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Degree of protection | IP40 | ||
Material housing | PA-reinforced | ||
Pneumatic connection | Push-in sleeve QS-6 | ||
Type of mounting | Plug-in | ||
Electrical connection | 3-wire Cable Open end | ||
Operational voltage range DC | 10 V ... 30 V | ||
Min. load resistance voltage output | 15 kOhm | ||
Analogue output | 1 - 5 V | ||
Repetition accuracy in ± %FS | 0,3 %FS | ||
Ambient temperature | 0 °C ... 50 °C | ||
Note on operating and pilot medium | Lubricated operation possible | ||
Overload pressure | 217,5 psi | ||
Start value for pressure measuring range | 0 psi | ||
Measured variable | Relative pressure | ||
Certificate issuing authority | UL E322346 | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive |
Suitability for the production of Li-ion batteries | Metals with more than 1% copper, zinc or nickel by mass are excluded from use. Exceptions are nickel in steel, chemically nickel-plated surfaces, printed circuit boards, cables, electrical plug connectors and coils | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Material sealing ring | FPM | ||
Product weight | 35 g | ||
Mounting position | optional | ||
Cable length | 2,5 m | ||
Reverse polarity protection | For all electrical connections | ||
Short circuit current rating | For all electrical connections | ||
Rise time | 1 ms | ||
Temperature coefficient in ± %FS/K | 0,05 %FS/K | ||
Accuracy in ± % FS | 3 %FS | ||
Media temperature | 0 °C ... 50 °C | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
End value for pressure measuring range | 145 psi | ||
Measurement method | Piezoresistive pressure sensor | ||
Note on materials | RoHS-compliant | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Approval | RCM trademark c UL us - Recognized (OL) |