Pollution degree | 3 | ||
Protection class | III | ||
Insulation voltage | 50 V | ||
Setting range of angular detection | 0 deg ... 270 deg | ||
Position indicator | Yellow/black | ||
Product weight | 1.000 g | ||
Max. cable length | 30 m | ||
Cable fitting | M20 | ||
Electrical connection | 9-pin Screw terminal Plug-in | ||
No-load supply current | 12 mA ... 20 mA | ||
Overload protection | Available | ||
Repetition accuracy analogue output in ± ° | 1 deg | ||
Ambient temperature | -20 °C ... 80 °C | ||
Measured variable | Rotation angle | ||
Explosion ambient temperature | -20°C <= Ta <= +80°C | ||
Explosion ignition protection type for dust | Ex tc IIIC T90°C X Dc IP65 | ||
Explosion ignition protection type for gas | Ex nA IIC T5 X Gc | ||
Explosion protection | Zone 2 (ATEX) Zone 22 (ATEX) Zone 2 (RU) Zone 22 (RU) | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
Design | Angular |
Corrosion resistance class CRC | 3 - high corrosion stress | ||
Immunity to surge | 0,8 kV | ||
Degree of protection | IP65 | ||
Setting options | Teach-in Teach-in via electrical connection | ||
Material housing | Wrought aluminium alloy | ||
Mounting position | optional | ||
Permissible cable diameter | 5 mm ... 13 mm | ||
Connectable nominal cross section conductor | 2,5 mm² | ||
Reverse polarity protection | For all electrical connections | ||
Operational voltage range DC | 15 V ... 30 V | ||
Short circuit current rating | yes | ||
Analogue output | 4 - 20 mA | ||
Measuring principle | Magnetic Hall | ||
Note on materials | RoHS-compliant | ||
Explosion protection certification outside the EU | EPL Dc (RU) EPL Gc (RU) | ||
ATEX category dust | II 3D | ||
ATEX category gas | II 3G | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Explosion Protection Directive (ATEX) | ||
Based on standard | VDI/VDE 3845 (NAMUR) |