Approval | RCM trademark | ||
Explosion protection | Zone 0 (ATEX) Zone 1 (ATEX) Zone 2 (ATEX) Zone 20 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) Zone 0 (IEC-EX) Zone 20 (IEC-EX) Zone 0 (CN) Zone 20 (CN) | ||
Explosion ignition protection type for gas | Ex ia IIC T6/T5 Ga | ||
Explosion ignition protection type for dust | Ex i IIIC Txx°C Da | ||
Explosion ambient temperature | See ATEX certificate See IECEx certificate | ||
Effective internal inductivity Li | 100 µH | ||
Max. intrinsically safe circuit input parameter | See IECEx certificate See ATEX certificate | ||
Note on materials | RoHS-compliant | ||
Measuring principle | Inductive | ||
Switching output | NAMUR | ||
Max. switching frequency | 2.000 Hz | ||
Off-state current | 0 mA ... 0,5 mA | ||
Electrical connection | Screw terminal | ||
Electrical connection 1, cable outlet | Straight | ||
Electrical connection 1, number of connections/cores | 10 | ||
Cable fitting | M20x1.5 | ||
Dimensions (W x L x H) | 114 mm x 98 mm x 122 mm | ||
Mounting position | optional | ||
Housing colour | grey | ||
Material seals | NBR | ||
Material screws | High-alloy stainless steel | ||
Material snap ring | High-alloy stainless steel | ||
Material cover cap | PC | ||
Setting range of angular detection | 0 deg ... 90 deg | ||
Degree of protection | IP67 NEMA 4/4X | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
LABS (PWIS) conformity | VDMA24364 zone III |
CE mark (see declaration of conformity) | To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive | ||
ATEX category gas | II 1G | ||
ATEX category dust | II 1D | ||
Explosion protection certification outside the EU | EPL Da (CN) EPL Da (IECEx) EPL Ga (CN) EPL Ga (IEC-EX) | ||
Max. input voltage Ui | 16 V | ||
Effective internal capacitance Ci | 100 nF | ||
Certificate issuing authority | FTZU 17 ATEX 0105X GYJ20.1409X IECEx FTZU 17.0017X | ||
Safety Integrity Level (SIL) | SIL 2 | ||
Ambient temperature | -20 °C ... 80 °C | ||
Switching element function | N/C contact | ||
Max. output current DC | 3 mA | ||
Operational voltage range DC | 8,2 V | ||
Electrical connection 1, connection type | Terminal strip | ||
Electrical connection 1, connector system | Spring-loaded terminal | ||
Connectable nominal cross section conductor | 0,25 mm² ... 2,5 mm² | ||
Permissible cable diameter | 6 mm ... 12 mm | ||
Type of mounting | On flange according to ISO 5211 | ||
Product weight | 800 g | ||
Material housing | Die-cast aluminium | ||
Material shaft | High-alloy stainless steel | ||
Material mounting bracket | High-alloy stainless steel | ||
Material disc | High-alloy stainless steel | ||
Position indicator | Yellow/red | ||
Storage temperature | -20 °C ... 50 °C | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Pollution degree | 3 |