Pollution degree | 3 | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Storage temperature | -20 °C ... 60 °C | ||
Position indicator | Yellow/red | ||
Material snap ring | High-alloy stainless steel | ||
Material mounting bracket | High-alloy stainless steel | ||
Material shaft | High-alloy stainless steel | ||
Material housing | Die-cast aluminium | ||
Product weight | 1.700 g | ||
Connection point for positioner and position sensor conforms to standard | VDI/VDE 3845 size AA 1 | ||
Cable fitting | M20x1.5 | ||
Electrical connection | 10-pin Screw terminal | ||
No-load supply current | ≤ 15 mA | ||
Short circuit current rating | Pulsed | ||
Voltage drop | ≤ 3 V | ||
Switching element function | N/O contact | ||
Ambient temperature | -20 °C ... 60 °C | ||
Safety Integrity Level (SIL) | SIL 2 | ||
Certificate issuing authority | 18-GA4BO-0516X 18-GA4BO-0517X DNV 16.0067X FTZU 15 ATEX 0095X GYJ 16.1497X IECEx FTZU 15.0014X KCC-18-GA4BO | ||
Explosion protection certification outside the EU | EPL Db (BR) EPL Db (CN) EPL Db (IEC-EX) EPL Db (IN) EPL Db (KR) EPL Gb (BR) EPL Gb (CN) EPL Gb (IECEx) EPL Gb (IN) EPL Gb (KR) | ||
ATEX category dust | II 2D | ||
ATEX category gas | II 2G | ||
CE mark (see declaration of conformity) | To EU EMC Directive To EU Explosion Protection Directive (ATEX) | ||
Based on standard | EN 60947-5-2 ISO 5211 VDI/VDE 3845 |
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Degree of protection | IP67 | ||
Setting range of angular detection | 0 deg ... 90 deg | ||
Material disc | High-alloy stainless steel | ||
Material indicator | PC | ||
Material screws | High-alloy stainless steel | ||
Material seals | NBR | ||
Housing colour | Silver | ||
Mounting position | optional | ||
Type of mounting | On flange according to ISO 5211 Via mounting bracket | ||
Connectable nominal cross section conductor | 0,25 mm² ... 2,5 mm² | ||
Reverse polarity protection | For all electrical connections | ||
Operational voltage range DC | 10 V ... 30 V | ||
Off-state current | 0 mA ... 0,5 mA | ||
Max. output current DC | 100 mA | ||
Switching output | NPN | ||
Measuring principle | Inductive | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant | ||
Explosion ambient temperature | -20°C <= Ta <= +60°C | ||
Explosion ignition protection type for dust | Ex tb IIIC T61°C Db | ||
Explosion ignition protection type for gas | Ex db IIC T6 Gb | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) Zone 1 (BR) Zone 21 (BR) Zone 1 (IEC-EX) Zone 21 (IEC-EX) Zone 1 (KR) Zone 21 (KR) Zone 1 (CN) Zone 21 (CN) | ||
Approval | RCM trademark | ||
Design | Angular |