Specifications
Parker's pilot operated sequence valves can be internally or externally piloted to allow multiple actuators to work in sequence based on pressure settings; working with flows up to 152 lpm (40 gpm) and pressures up to 380 bar (5500 psi).
Weight | 450g |
---|
Installation Torque | 51-55 lb-ft, 69-75 Nm | ||
Adjustment Type | Knob Adjust | ||
Rated Flow (gpm) | 15 | ||
Cracking Pressure (psi) | N/A | ||
Flow Rate | 15 Gal/min, 56.3 L/min | ||
Pilot Location | External | ||
Leak Rate | 82 @ 3000 PSI (210 BAR) cm3/min | ||
Pressure Control Range | 100-2000 psi, 6.9-138 bar | ||
Standard Setting Pressure | 1000 psi, 69 bar | ||
Cracking Pressure | N/A, N/A | ||
Body Material | N/A | ||
Filter Efficiency Rating | ISO 4406:1999 Code 18/16/13 |
Pilot Option | External | ||
Drain Option | Internal | ||
Pressure Range Adjustment (psi) | 100-2000 | ||
Seal Material | D-Ring (Standard) | ||
Maximum Inlet Pressure Rating | 5500 psi, 380 bar | ||
Maximum Tank Pressure | 5000 psi, 350 bar | ||
Cavity Size | C10-3 | ||
Adjustment Mechanism | Knob Adjust | ||
Pressure Control Sensitivity | 570 per turn psi, 39.3 per turn bar | ||
Valve Material | All parts steel. All operating parts hardened steel | ||
Maximum Kinematic Viscosity | Mineral-based or synthetic with lubricating properties at viscosities of 45-2000 SSU (6 to 420 cSt) cSt | ||
Weight | 1 lb, 0.45 kg |