Type of actuation | Electric | ||
Duty cycle | 100% | ||
Insulation material class of enamelled wire | H | ||
Permissible voltage fluctuations | +/- 10 % | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
Certificate issuing authority | DNVGL-TAA000011J | ||
ATEX category dust | II 3D | ||
Explosion ignition protection type for dust | Ex tc IIIC T95°C/T105°C X Dc | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Degree of protection | IP65 | ||
Product weight | 95 g | ||
Type of mounting | Via knurled nut | ||
Material housing | Polymer Steel | ||
Material winding | Copper |
Mounting position | optional | ||
Insulation material class | F | ||
Characteristic coil data | 24 V DC: 2.1 W | ||
Maritime classification | See certificate | ||
Explosion protection | Zone 2 (ATEX) Zone 22 (ATEX) | ||
ATEX category gas | II 3G | ||
Explosion ignition protection type for gas | Ex nA IIC T5/T4 X Gc | ||
Explosion ambient temperature | -20°C <= Ta <= +60°C | ||
LABS (PWIS) conformity | VDMA24364-B2-L | ||
Ambient temperature | -20 °C ... 60 °C | ||
Electrical connection | Type A To DIN EN 175301-803 | ||
Note on materials | RoHS-compliant | ||
Material electrical contact | Brass |