Specifications
Series (VACN) | Solenoid coil, series N |
---|---|
Solenoid coil type (N) | Solenoid coil N for armature tube 9 mm |
Electrical connection (K1) | Cable |
Nominal operating voltage (1) | 24 V DC |
Cable length [m] (10) | 10 |
---|---|
EU certification (EX4) | II 2GD |
Certification | None |
Type of ignition protection (M) | Encapsulation |
Characteristic coil data | 24 V DC: 2.6 W | ||
Product weight | 762 g | ||
Cable diameter | 7 mm | ||
Type of mounting | Via knurled nut | ||
Material housing | Polymer Steel | ||
Type of actuation | Electric | ||
Duty cycle | 100% | ||
Insulation material class of enamelled wire | H | ||
Maritime classification | See certificate | ||
Explosion protection certification outside the EU | EPL Db (IEC-EX) EPL Gb (IECEx) | ||
Certificate issuing authority | IECEx PTB 15.0016X PTB 14 ATEX 2027 X | ||
ATEX category dust | II 2D | ||
Explosion ignition protection type for dust | Ex mb tb IIIC T80°C Db | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Degree of protection | IP65 |
Ambient temperature | -20 °C ... 50 °C | ||
Electrical connection | Cable | ||
Cable length | 10 m | ||
Note on materials | RoHS-compliant | ||
Material winding | Copper | ||
Mounting position | optional | ||
Insulation material class | F | ||
Permissible voltage fluctuations | +/- 10 % | ||
CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) Zone 1 (IEC-EX) Zone 21 (IEC-EX) | ||
ATEX category gas | II 2G | ||
Explosion ignition protection type for gas | Ex mb IIC T6 Gb | ||
Explosion ambient temperature | -20°C <= Ta <= +50°C | ||
LABS (PWIS) conformity | VDMA24364-B2-L |