Specifications
Series (VACS) | Solenoid coil VACS |
---|---|
Solenoid coil type (C) | Solenoid coil width of 18 mm for armature tube of 8 mm |
Electrical connection (R3) | Single plug M12 A-coded, according to EN 61076-2-101 |
Nominal operating voltage (1) | 24 V DC |
---|---|
Circuitry (R) | Holding current reduction with integrated protective circuit |
Display (L) | LED |
Type of mounting | Via knurled nut | ||
Material housing | PA Steel | ||
Material winding | Copper | ||
Signal status display | LED | ||
Duty cycle | 100% | ||
Nominal pick-up current per solenoid coil | 108 mA till 80 ms | ||
Characteristic coil data | 24 V DC: low-current phase 0.36 W, high-current phase 2.6 W | ||
Approval | RCM trademark | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Ambient temperature | -10 °C ... 60 °C | ||
Electrical connection | M12x1, A-coded to EN 61076-2-101 |
Note on materials | RoHS-compliant | ||
Material solenoid coil | Copper Steel Thermoplastic | ||
Mounting position | optional | ||
Max. switching frequency | 5 Hz | ||
Insulation material class of enamelled wire | H | ||
Nominal current with current reduction | 15 mA after 80 ms | ||
Permissible voltage fluctuations | +/- 10 % | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Degree of protection | IP65 | ||
Max. cable length | 30 m |