Valve function | 3-way proportional pressure regulator | ||
Type of piloting | Direct | ||
Type of reset | Magnetic spring | ||
Mounting position | optional | ||
Nominal size | 6 mm | ||
Display type | LED | ||
Operating pressure | 4 bar ... 8 bar | ||
Information on lowering speed | When the manual exhaust is actuated with cylinder diameter 80 mm, transmission ratio 1:1 and 100 kg load. | ||
Operating medium | Compressed air to ISO 8573-1:2010 [6:4:4] | ||
Degree of protection | IP65 | ||
Approval | RCM trademark | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
LABS (PWIS) conformity | VDMA24364 zone III | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Corrosion resistance class CRC | 1 - Low corrosion stress | ||
Nominal operating voltage DC | 24 V | ||
Residual ripple | 5 % | ||
Current consumption | 120 mA | ||
Duty cycle | 100% | ||
Diagnostic function | Display via LED | ||
Field bus, connection type | Plugs | ||
Field bus, connection pattern | 5 | ||
Electrical connection for drive, connection type | Socket | ||
Electrical connection for drive, number of pins/wires | 8 | ||
Electrical connection for valve, connection technology | Plug pattern type C to industry standard, 9.4 mm | ||
Type of mounting | Direct mounting via M5 thread | ||
Pneumatic connection, port 2 | G3/8 | ||
Pneumatic connection for control component | G1/8 | ||
Material housing | Anodised wrought aluminium alloy |
Design | Piston gate valve With integrated pressure sensors | ||
Type of actuation | Electric | ||
Flow direction | Non-reversible | ||
Sealing principle | Hard | ||
Short circuit current rating | yes | ||
Standard nominal flow rate | 725 l/min | ||
Typical lowering speed | 15 mm/s | ||
Ambient temperature | 0 °C ... 50 °C | ||
Note on operating and pilot medium | Lubricated operation not possible Maximum particle size 5 µm | ||
Note on degree of protection | In assembled state | ||
KC mark | KC-EMV | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Note on materials | RoHS-compliant | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Instructions on use | The product is suitable for industrial purposes only. Measures to eliminate radio interference may be required in residential areas. | ||
Operational voltage range DC | 21,6 V ... 26,4 V | ||
Max. current consumption | 1,2 A | ||
Reverse polarity protection | For operating voltage | ||
Max. electrical power consumption | 33,5 W | ||
Max. cable length | 30 m | ||
Field bus, connection system | M12x1, A-coded according to EN 61076-2-101 | ||
Field bus, protocol | CAN bus with Festo protocol | ||
Electrical connection for drive, connection technology | M12x1, A-coded to EN 61076-2-101 | ||
Electrical connection for valve, connection type | Plugs | ||
Electrical connection for valve, number of pins/wires | 2 | ||
Pneumatic connection, port 1 | G3/8 | ||
Pneumatic connection, port 3 | G3/8 | ||
Product weight | 1.550 g | ||
Material seals | FPM HNBR NBR |
Stock | Ask for quotation |
---|---|
Part number | 5318141 |
Manufacturer | Festo |
Quantity | Unit Price |
---|---|
1+ | $4,668.08 |