Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Approval | RCM trademark | ||
Note on materials | Contains paint-wetting impairment substances RoHS-compliant | ||
Measurement method | Pneumatic/electric pressure transducer | ||
Operating pressure | -1 bar ... 0 bar | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Ambient temperature | 0 °C ... 60 °C | ||
Hysteresis | 0,08 bar ... 0,25 bar | ||
Operational voltage range DC | 10 V ... 30 V | ||
Type of mounting | With through-hole With H-rail Either: | ||
Pneumatic connection | M5 | ||
Material housing | PA PET POM | ||
Setting range threshold value | -0,8 bar ... -0,2 bar |
Symbol | 991,472 | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Measured variable | Relative pressure | ||
Pressure measuring range | -0,8 bar ... -0,2 bar | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:-:-] | ||
Media temperature | 0 °C ... 60 °C | ||
Switching element function | Changeover switch | ||
Max. output current | 2.500 mA | ||
Electrical connection | 4-pin Screw terminal | ||
Mounting position | optional | ||
Product weight | 56 g | ||
Switching status indication | Yellow LED | ||
Degree of protection | IP20 |