Specifications
Series (VYKA) | Solenoid valve VYKA |
---|---|
Directional control valve type (F) | Flanged valve |
Size (7) | Size 7 |
Valve function (M32) | 3/2-way valve, normally closed or open |
Nominal width (12) | 1.2 mm |
Pressure range [bar] (D2) | 0 ... 2 |
---|---|
Housing material (P) | PEEK |
Diaphragm and sealing material (F) | FFPM |
Nominal operating voltage (5Y) | 12 V DC to 26 V DC |
Electrical connection (Q7) | Plug socket, connection pattern Q |
Product weight | 10,9 g | ||
Material membrane | FFPM | ||
Note on materials | RoHS-compliant | ||
Degree of protection | IP40 | ||
Instructions on use | For indoor use only | ||
Design | Rocker valve with diaphragm seal | ||
Material in contact with the medium | FFPM PEEK | ||
Valve function | 3/2-way, monostable, open/closed | ||
Flow direction | Reversible with restrictions | ||
Type of piloting | Direct | ||
Manual override | None | ||
Type of mounting | Via through-hole for M2 screw | ||
Electrical connection 1, connector system | Connection pattern Q7 | ||
Electrical connection 1, connection pattern | 00997312 | ||
Grid dimension | 7,5 mm | ||
Medium | Liquid media Gaseous media | ||
Internal volume | 16 µl fluid chamber valve 26 µl valve with fluid connections | ||
Medium temperature gaseous media | 15 °C ... 50 °C | ||
Storage temperature | -20 °C ... 70 °C | ||
Medium pressure, reversible | 0 psi ... 14,5 psi | ||
Operational voltage range DC | 12 V ... 26 V | ||
Permissible voltage fluctuations | +/- 10 % | ||
Information on power consumption | Low-current phase 0.3 W, high-current phase 3.5 W for 60 ms, in combination with VAVE-K1-… | ||
Insulation material class | B | ||
Max. switching frequency | 6 Hz | ||
Switch-on time for fluids | 5 ms | ||
Switch-off time for fluids | 6 ms | ||
Standard nominal flow rate | 11 l/min | ||
Flow rate Kv | 0,35 l/min | ||
Water flow rate at max. operating pressure | 0.5 l/min 0.03 m³/h |
Material housing | PA-reinforced PEEK PPA reinforced | ||
Material seals | FFPM | ||
LABS (PWIS) conformity | VDMA24364 zone III | ||
Note on degree of protection | In assembled state | ||
Corrosion resistance class CRC | 0 - No corrosion stress | ||
Sealing principle | Soft | ||
Suitable for use with food | See supplementary material information | ||
Nominal size | 1,2 mm | ||
Type of actuation | Electric | ||
Type of reset | Mechanical spring | ||
Mounting position | optional | ||
Electrical connection 1, connection type | Socket | ||
Electrical connection 1, number of connections/cores | 2 | ||
Size | 7 | ||
Fluid connection | Flange | ||
Note on the medium | Observe resistance of materials that come into contact with the media Maximum particle size 5 µm | ||
Media temperature for fluids | 15 °C ... 50 °C | ||
Ambient temperature | 15 °C ... 50 °C | ||
Medium pressure | 0 psi ... 29 psi | ||
Burst pressure | 333,5 psi | ||
Note on operational voltage range DC | With electrical sub-base VAVE-K1-… | ||
Electrical power consumption | 3,5 W | ||
Characteristic coil data | 12 - 26 V DC: low-current phase 0.06 W, high-current phase 2.2 W | ||
Duty cycle | 100% in conjunction with holding current reduction Observe the notes on operating the solenoid valves. | ||
Note on switching frequency | Dependent on the ambient temperature and installation state | ||
Switching time on gaseous media | 5 ms | ||
Switching time off gaseous media | 5 ms | ||
Note on standard nominal flow rate | At pressure drop from 1 -> 0 bar (gaseous media) | ||
Note on flow rate Kv | For medium water Pressure difference 1 bar | ||
Symbol | 00992967 |