model | zse10 | ||
set pressure range/pressure display range | 10.0 to ?105.0 kpa | ||
minimum unit setting | 0.1 kpa | ||
power supply voltage | 12 to 24 vdc ?10%, ripple (p-p) 10% or less (with power supply polarity protection) | ||
switch output | npn or pnp open collector 2 outputs (selectable) | ||
maximum applied voltage | 28 v (with npn output) | ||
response time | 2.5 ms or less (response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms) | ||
repeat accuracy | ?0.2% f.s. ?1 digit | ||
hysteresis - window comparator mode | variable (0 or above) note) | ||
analog output - voltage output - linearity | ?1% f.s. or less | ||
Display | 3 1/2 digit, 7-segment indicator, 1-color display (red) | ||
indicator light | lights up when output is turned on. out1: green out2: red | ||
environmental resistance - operating temperature range | operating: ?5 to 50c, stored: ?10 to 60c (no freezing or condensation) | ||
environmental resistance - withstand voltage | 1000 vac for 1 min. between live parts and enclosure | ||
environmental resistance - vibration resistance | 10 to 150 hz, at the smaller of amplitude 1.5 mm or 20 m/s2 in x, y, z directions for 2 hours each (de-energized) | ||
temperature characteristics | ?2% f.s. (at 25c in an operating range of ?5 to 50c) | ||
Standard | compliant with ce marking, ul (csa) and rohs compliant |
rated pressure range | 0.0 to ?101.0 kpa | ||
withstand pressure | 500 kpa | ||
fluid | air, non-corrosive gas, non-flammable gas | ||
Current consumption | 40 ma or less | ||
maximum load current | 80 ma | ||
residual voltage | 2 v or less (with load current of 80 ma) | ||
short circuit protection | yes | ||
hysteresis - hysteresis mode | variable (0 or above) note) | ||
analog output - voltage output - output voltage (rated pressure range) | 1 to 5 v ?2.5% f.s. | ||
analog output - voltage output - output impedance | approx. 1 k | ||
display accuracy | ?2% f.s. ?1 digit (at 25c ?3c ambient temperature) | ||
environmental resistance - enclosure | ip40 | ||
environmental resistance - operating humidity range | operating and stored: 35 to 85% rh (no condensation) | ||
environmental resistance - insulation resistance | 50 m or more between live parts and enclosure (at 500 vdc mega) | ||
environmental resistance - impact resistance | 100 m/s2 in x, y, z directions 3 times each (de-energized) | ||
lead wire | oil-resistant vinyl cabtire cable5 cores, cross section: 0.15 mm2 (awg26) insulator o.d.: 1.0 mm | ||
Weight | .14550 lb |