model | zse30a | ||
set pressure range | 10.0 to ?105.0 kpa | ||
minimum unit setting | 0.1 kpa | ||
power supply voltage | 12 to 24 vdc ?10%, ripple (p-p) 10% or less (with power supply polarity protection) | ||
switch output | npn or pnp open collector 1 output, npn or pnp open collector 2 outputs (selectable) | ||
maximum applied voltage | 28 v (at npn output) | ||
response time | 2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms) | ||
repeatability | ?0.2% f.s. ?1 digit | ||
hystere- sis - window comparator mode | variable (0 or above) note 1) | ||
analog output - note 2) voltage output - linearity | approx. 1 k | ||
analog output - note 3) current output - output current (rated pressure range) | ?1% f.s. or less | ||
Display | 4-digit, 7-segment, 2-color lcd (red/green) | ||
indicator light | lights up when switch output is turned on. out1: green, out2: red | ||
environ- ment resistance - operating temperature range | operating: 0 to 50c, stored: ?10 to 60c (no freezing or condensation) | ||
environ- ment resistance - withstand voltage | 1000 vac for 1 minute between live parts and case | ||
environ- ment resistance - vibration resistance | 10 to 150 hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in x, y, z directions, for 2 hours each (non-energized) | ||
temperature characteristics | ?2% f.s. (based on 25c) | ||
Standards | ce marking, ul/csa, rohs compliance |
rated pressure range | 0.0 to ?101.0 kpa | ||
withstand pressure | 500 kpa | ||
applicable fluid | air, non-corrosive gas, non-flammable gas | ||
Current consumption | 40 ma or less | ||
maximum load current | 80 ma | ||
residual voltage | 1 v or less (with load current of 80 ma) | ||
short circuit protection | yes | ||
hystere- sis - hysteresis mode | variable (0 or above) note 1) | ||
analog output - note 2) voltage output - output voltage (rated pressure range) | 1 to 5v ?2.5% f.s. | ||
analog output - note 3) current output - output impedance | 4 to 20 ma ?2.5% f.s. | ||
analog output - note 3) current output - load impedance | maximum load impedance: power supply voltage 12 v: 300 , power supply voltage 24 v: 600 minimum load impedance: 50 | ||
display accuracy | ?2% f.s. ?1 digit (ambient temperature of 25 ?3c) | ||
environ- ment resistance - enclosure | ip40 | ||
environ- ment resistance - operating humidity range | operating/stored: 35 to 85% rh (no condensation) | ||
environ- ment resistance - insulation resistance | 50 m or more between live parts and case (at 500 vdc mega) | ||
environ- ment resistance - impact resistance | 100 m/s2 in x, y, z directions, 3 times each (non-energized) | ||
lead wire | oilproof heavy-duty vinyl cable, 3 cores ?3.5, 2 m4 cores conductor area: 0.15 mm2 (awg26), insulator o.d.: 1.0 mm | ||
Weight | .28660 lb |